  18-1 ? 2009 schneider electric all rights reserved 18 iec contactors and starters table of contents section 18 tesys ? iec contactors and starters tesys d contactors (p. 18-4) tesys f contactors (p. 18-5) gv7 manual motor starters and protectors (p. 18-35) gv3p (p.18-33) lub ? 2 (p. 18-28) gv2p21 (p.18-33) new! contactors tesys d 18-4 tesys d reversing 18-6 tesys f 18-5 tesys k 18-24 tesys d and f accessories 18-8 tesys k accessories 18-27 motor starters and protectors tesys u 18-28 gv2, gv3, gv7 manual motor protectors 18-33 enclosed d-line 18-21 gv accessories 18-34 ls1d fuse block 18-36 overload relays tesys d 18-4 tesys f 18-5 tesys d and f accessories 18-16 tesys k 18-24 tesys k accessories 18-27 tesys t 16-92 soft start module ats01 18-32 replacement parts tesys d coils 18-17 tesys f coils 18-20 tesys f contact tips, etc. 18-13 wiring systems gv-line bus bars 18-37 tesys d quickfit 18-38 ak5 18-39 dimensions 18-40 for more information on lighting, definite pu rpose (dp), and elevator ratings for tesys d and tesys f contactors, please refer to catalog 8502ct9901. for more information on machine safety applications using tesys d and tesys f, please refer to catalog mkted208051en-us. see our website, www.schneider-electric.us, for ul 508a short circuit ratings (sccr).
www.schneider-electric.us 18 iec contactors and starters 18-2 ? 2009 schneider electric all rights reserved 3 pole contactors tesys ? d ac and dc contactors refer to catalog 8502ct9901 s on lc1d09 - lc1d65a, for spring terminals versions add '3' to the catalog number prior to adding the voltage code (ex. lc1d12g7 becomes lc1d123g7 and lc1d40ag7 becomes lc1d40a3g7 - note that 40a to 65a spring terminals are only on the control terminations and not on power terminations). no price adder for this modification. t on lc1d09 - lc1d65a and lc1dt20 through lc1dt80a, for ring tongue versions add '6' to the catalog number prior to adding the vo ltage code (ex. lc1d09g7 becomes lc1d096g7 and lc1d50ag7 becomes lc1d50a6g7). no price adder for this modification. note: to be used for interpretation of current catalog numbers only. lc _____ d _____ _____ _____ _____ full voltage, non-reversing 1 full voltage, reversing 2 tesys d 3 pole contactors 9a to 150a contactor ac-3 full load amps (fla) 9a fla 09 12a fla 12 18a fla 18 25a fla 25 32a fla 32 38a fla (not marketed in us) 38 40a fla 40 50a fla 50 65a fla 65 80a fla 80 95a fla (not marketed in us) 95 115a fla 115 150a fla 150 everlink power connection (40a to 65a only) a no everlink power connection (9a to 32a, 80a to 150a) blank termination options (choose one) screw termination blank spring terminations s 3 ring tongue terminations t 6 slip-on terminations (9a to 12a only) 9 coil voltage (choose one) ac coils (50/60 hz) dc coils (standard) dc coils low consumption available for 9 to 38 amp only 12v j7 12v jd 5v al 21v z7 21v zd 12v jl 24v b7 24v bd 21v zl 36v c7 36v cd 24v bl 42v d7 48v ed 48v el 48v e7 60v nd 72v sl 60v ee7 72v sd 96v dl 100v k7 110v fd 110v fl 110v f7 125v gd 220v ml 115v fe7 220v md 250v ul 120v g7 250v ud 127v fc7 440v rd 200v l7 208v le7 220v m7 230v p7 240v u7 277v w7 380v q7 400v v7 415v n7 440v r7 480v t7 500v s7 575v sc7 600v x7 660v y5 (50 hz only)
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-3 2, 3, and 4 pole contactors tesys ? f ac and dc contactors refer to catalog 8502ct9901 lc _____ f _____ _____ _____ _____ full voltage, non-reversing 1 full voltage, reversing 2 tesys f 2, 3, and 4 pole contactors 115a to 800a contactor ac-3 full load amps (fla) 115a fla 115 150a fla 150 185a fla 185 225a fla 225 265a fla 265 330a fla 330 400a fla 400 500a fla 500 630a fla 630 780a fla 780 800a fla 800 number of poles 2 poles (400a, 500a, and 630a only) 2 3 poles (all sizes) blank 4 poles (all sizes except 800a) 4 termination options - pu rchase lugs separately blank coil voltage (choose one and note c ontactor size it can be used on) ac coils for use on: dc coils for use on: 24v (50 hz) b5 lc1f115 - f225 24v bd lc1f115 - f400 24v (60 hz) b6 lc1f115 - f225 48v ed lc1f115 - f630 24v (40-400 hz) b7 lc1f225 - f400 110v fd lc1f115 - f780 42v (50 hz) d5 lc1f115 - f225 110v fw lc1f800 48v (50 hz) e5 lc1f115 - f225 125v gd lc1f115 - f780 48v (60 hz) e6 lc1f115 - f225 220v md lc1f265 - f780 48v (40-400 hz) e7 lc1f115 - f630 220/240v mw lc1f800 110v (50 hz) f5 lc1f115 - f225 250v ud lc1f115 - f780 110v (60 hz) f6 lc1f115 - f225 380/400v qw lc1f800 110v (40-400 hz) b7 lc1f115 - f780 440v rd lc1f115 - f780 115v (50 hz) fe5 lc1f115 - f225 115v (40-400 hz) fe7 lc1f115 - f780 120v (60 hz) g6 lc1f115 - f225 120v (40-400 hz) g7 lc1f115 - f400 120v (40-400 hz) f7 lc1f500 - f780 127v (60 hz) g6 lc1f115 - f225 127v (40-400 hz) g7 lc1f115 - f780 200/208v (60 hz) l6 lc1f115 - f225 200/208v (40-400 hz) l7 lc1f265 - f780 208v (40-400 hz) l7 lc1f115 - f225 220v (50 hz) m5 lc1f115 - f225 220v (60 hz) m6 lc1f115 - f225 220v (40-400 hz) m7 lc1f115 - f780 230v (50 hz) p5 lc1f115 - f225 230v (40-400 hz) p7 lc1f115 - f800 240v (50 hz) u5 lc1f115 - f225 240v (60 hz) u6 lc1f115 - f225 240v (40-400 hz) u7 lc1f115 - f780 277v (50 hz) w5 lc1f115 - f225 277v (40-400 hz) w7 lc1f115 - f780 380v (50 hz) q5 lc1f115 - f225 380v (60 hz) q6 lc1f115 - f225 380v (40-400 hz) q7 lc1f115 - f780 400v (50 hz) v5 lc1f115 - f225 400v (40-400 hz) v7 lc1f115 - f800 415v (50 hz) n5 lc1f115 - f225 415v (40-400 hz) n7 lc1f115 - f780 440v (50 hz) r5 lc1f115 - f225 440v (40-400 hz) r7 lc1f115 - f780 460/480v (60 hz) q6 lc1f115 - f225 480v (40-400 hz) n7 lc1f780 500v (50 hz) s5 lc1f115 - f225 500v (40-400 hz) s7 lc1f115 - f780 600v (40-400 hz) x7 lc1f500 - f630 660v (60 hz) y6 lc1f115 - f225
www.schneider-electric.us 18 iec contactors and starters 18-4 ? 2009 schneider electric all rights reserved contactors & overload relays tesys ? d non-reversing refer to catalog 8502ct9901 tesys d contactor accessories . . . . . . . . . . . . . . . . . . . . pages 18-8 to 18-11 tesys d overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 tesys d replacement coils. . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19 dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 tesys t. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 16-91 lc1d09 lc1d40a lc1d093 lc1d115 lrd22 lrd3 e164862 ccn nldx lr43364 class 3211 04 table 18.1: 3- or 4-pole screw terminal connections maximum horsepower ratings maximum current utilization categories no of poles instantaneous auxiliary contacts catalog number a $ price single phase three phase inductive ac3 amperes resistive ac1 amperes n.o. n.c. n.o. n.c. 115 v hp 230 v hp 200 v hp 230 v hp 460 v hp 575 v hp ac coils dc coils 0.51 2 2 57.59 20 3 0 11 lc1d09 cde 94.00 119.00 ??????? 4 lc1dt20 c 94.00 119.00 ??????? 22 lc1d098 c 94.00 119.00 12337.51012 25 3 0 11 lc1d12 cde 119.00 149.00 ??????? 4 lc1dt25 c 119.00 149.00 ??????? 22 lc1d128 c 119.00 149.00 1355101518 32 3 0 11 lc1d18 cd 136.00 160.00 ??????? 4 lc1dt32 c 149.00 183.00 ??????? 22 lc1d188 c 149.00 183.00 2 3 7.5 7.5 15 20 25 40 3 0 11 lc1d25 cd 151.00 181.00 ??????? 4 lc1dt40 c 193.00 240.00 ??????? 22 lc1d258 c 193.00 240.00 2 5 10 10 20 30 32 50 3 0 1 1 lc1d32 cd 172.00 213.00 3 5 10 10 30 30 40 60 3 0 1 1 lc1d40a 218.00 275.00 ??????? 4 00lc1dt60a 296.00 353.00 3 7.5 15 15 40 40 50 80 3 011 lc1d50a 234.00 291.00 5 102020405065 3 lc1d65a 322.00 379.00 ??????? 4000lc1dt80a 446.00 503.00 7.5152530606080 125 3 0 1 1 lc1d80 363.00 420.00 ??????? 4 00 lc1d80004 b 489.00 524.00 ??????? 22 lc1d80008 b 489.00 524.00 ? ? 30 40 75 100 115 200 3 0 11 lc1d115 479.00 479.00 ? ? 40 50 100 125 150 3 lc1d150 696.00 696.00 ? ? ? ? ? ? ? 4 0 0 lc1d115004 630.00 630.00 a complete catalog number with coil voltage code from table on page 18-6; example, lc1d09g7. b for dc version of these devices replace the 'c' with 'p' (ex. lc1d80004** becomes lp1d80004**). this applies only to 80a 4 pole devices. c on lc1d09 - lc1d65a and lc1dt20 through lc1dt80a, for ring tongue versions add '6' to the catalog number prior to adding the vo ltage code (ex. lc1d09g7 becomes lc1d096g7 and lc1d50ag7 becomes lc1d50a6g7). no price adder for this modification. d on lc1d09 - lc1d65a, for spring terminals versions add '3' to the catalog number prior to adding the voltage code (ex. lc1d12g7 becomes lc1d123g7 and lc1d40ag7 becomes lc1d40a3g7 - note that 40a to 65a spring terminals are only on the control terminations and not on power terminations). no price adder for this modification. e on lc1d09 and lc1d12 only, for slip-on connector versions add "9" to the catalog number prior to adding the voltage code (ex. l c1d09g7 becomes lc1d099g7). no price adder for this modification. table 18.2: tesys d overload relays ? ambient compensated, bi-metallic direct mount current setting range amperes for direct mounting to lc1 ... class 10 with single phase sensitivity class 10 without single phase sensitivity class 20 with single phase sensitivity class 20 without single phase sensitivity $ price 0.10?0.16 d09?d32 lrd01 lr3d01 ?? 60.00 0.16?0.25 lrd02 lr3d02 ?? 0.25?0.40 lrd03 lr3d03 ?? 0.40?0.63 lrd04 lr3d04 ?? 0.63?1 lrd05 lr3d05 ?? 1?1.6 lrd06 lr3d06 ?? 1.6?2.5 lrd07 lr3d07 ?? 2.5?4 lrd08 lr3d08 lrd1508 lr3d1508a1 4?6 lrd10 lr3d10 lrd1510 lr3d1510a1 5.5?8 d09?d32 lrd12 lr3d12 lrd1512 lr3d1512a1 62.00 7?10 d09?d32 lrd14 lr3d14 lrd1514 lr3d1514a1 9?13 d12?d32 lrd16 lr3d16 lrd1516 lr3d1516a1 12?18 d18?d32 lrd21 lr3d21 lrd1521 lr3d1521a1 16?24 d25?d32 lrd22 lr3d22 ?? 17?25 d25?d32 ? ? lrd1522 lr3d1522a1 23?32 d25?d32 lrd32 lr3d32 ?? 73.00 23?28 d25?d32 ? ? lrd1530 lr3d1530a1 25?32 d25?d32 ? ? lrd1532 lr3d1532a1 30?38 d32 lrd35 lr3d35 ?? 9-13 d40a-d65a f lrd313 lr3d313 lrd313l ? 107.00 12-18 d40a-d65a f lrd318 lr3d318 lrd318l ? 16-25 d40a-d65a f lrd325 lr3d325 lrd325l ? 23-32 d40a-d65a f lrd332 lr3d332 lrd332l ? 30-40 d40a-d65a f lrd340 lr3d340 lrd340l ? 37-50 d40a-d65a f lrd350 lr3d350 lrd350l ? 48-65 d40a-d65a f lrd365 lr3d365 lrd365l ? 17-25 d40-d80 g lrd3322 lr3d3322 lr2d3522 lr3d3522 107.00 23-32 d40-d80 g lrd3353 lr3d3353 lr2d3553 lr3d3553 30-40 d40-d80 g lrd3355 lr3d3355 lr2d3555 lr3d3555 37-50 d50-d80 g LRD3357 lr3d3357 lr2d3557 lr3d3557 48-65 d50-d80 g lrd3359 lr3d3359 lr2d3559 lr3d3559 55?70 d65?d80 lrd3361 lr3d3361 lr2d3561 lr3d3561 127.00 63?80 d65?d80 lrd3363 lr3d3363 lr2d3563 lr3d3563 80?104 d80 lrd3365 ??? 80?104 d115?d150 lrd4365 ??? 362.00 95?120 d115?d150 lrd4367 ??? 110?140 d150 lrd4369 ??? f overload relays with everlink termination - direct mount to d40a to d65a only. g direct mount to old d2 style d40 to d65 (no everlink terminations) and to d80 only. i12 discount schedule
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-5 contactors & overload relays tesys ? f non-reversing refer to catalog 8502ct9901 a complete part number by adding coil voltage code from table below. for example: lc1f115g7. all contactors (except f780) include 1 n.o. coil interlock contact. tesys f contactor accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-11 tesys f overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . .page 18-16 tesys f replacement coils and parts . . . . . . . . . . pages 18-13, 18-18, 18-20 dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-42 to 18-49 lc1f115 e164862 ccn nldx lr43364 class 3211 04 table 18.3: tesys d overload relays ? solid state current setting range amperes for direct mounting beneath contractor lc1 class 10 class 20 $ price 60?100 d115?d150 lr9d5367 lr9d5567 298.00 90?150 d115?d150 lr9d5369 lr9d5569 298.00 table 18.4: tesys f 2-, 3-, and 4-pole contactors standard power rati ngs of 3-phase motors 50/60 hz in category ac-3 maximum current number of poles catalog number a $ price 200 v 208 v 220 v 240 v 460 v 480 v 575 v 600 v ac-3 ac-1 panel mount with screws hp hp hp hp a a 30 40 75 100 115 200 3lc1f115 479.00 4lc1f1154 630.00 40 50 100 125 150 250 3lc1f150 696.00 4lc1f1504 825.00 50 60 125 150 185 275 3lc1f185 938.00 4lc1f1854 1439.00 current rated 225 315 3lc1f225 1059.00 4lc1f2254 1935.00 60 75 150 175 265 350 3lc1f265 1179.00 4lc1f2654 1646.00 75 100 200 250 330 400 3lc1f330 1621.00 4lc1f3304 1846.00 100 125 250 300 400 500 2lc1f4002 1521.00 3lc1f400 1874.00 4lc1f4004 2133.00 150 200 400 500 500 700 2lc1f5002 4324.00 3lc1f500 4970.00 4lc1f5004 5617.00 250 300 600 800 630 1000 2lc1f6302 5917.00 3lc1f630 6474.00 4lc1f6304 7582.00 current rated 780 1600 3lc1f780 7788.00 4lc1f7804 9940.00 ? 450 800 900 800 1000 3 lc1f800 6676.00 table 18.5: tesys f 3-phase overload relays ? solid state separate mount b current setting range amps for direct mounting to contactor lc1 class 10 trip c catalog number class 20 c catalog number $ price 30?50 f115?f185 lr9f5357 lr9f5557 298.00 48?80 f115?f185 lr9f5363 lr9f5563 298.00 60?100 f115?f185 lr9f5367 lr9f5567 298.00 90?150 f115?f185 lr9f5369 lr9f5569 298.00 132?220 f185 d ?f265 lr9f5371 lr9f5571 298.00 200?330 f265?f500 lr9f7375 b lr9f7575 b 333.00 300?500 f265?f500 lr9f7379 b lr9f7579 b 737.00 380?630 f400?f630 lr9f7381 b lr9f7581 b 905.00 b when mounting overload relays lr9f5 57 to lr9f5 71 directly beneath the contactor, supporting the relays with a mounting plate is recommended. with overload relays lr9f7 75 to lr9f7 81, use of a support mounting plate is mandatory. c iec standard 60947-4 specifies the following trip times when the overload relay senses 7.2 times the setting current: class 10 ? between 4 and 10 seconds class 20 ? between 6 and 20 seconds d interconnection kit la7f407 is required to mount an lr9f 71 to an lc1f185. table 18.6: coil voltage codes h contactor hz 24 v 48 v 110 v 120 v 125 v 208 v 220 v 240 v 250 v 440 v 480 v 600 v ac d09?d150 50/60 b7 e7 f7 g7 ? le7 m7 u7 ? ? t7 e x7 ef lc1d80?lc1d150 only 60 b6 e6 f6 g6 ? l6 m6 u6 ? ? t6 x6 f 50 b5 e5 f5 ? ? ? m5 e u5???? f115, f150, and f185 50b5e5f5???m5u5???? 60 b6 e6 f6 g6 ? l6 m6 u6 ? ? q5 sc f265, and f330 40?400 b7 e7 f7 g7 ? l7 m7 u7 ? ? s7 i x7 f400? f780 40?400 ? e7 f7 g7 ? l7 m7 u7 ? ? n7 x7 g dc d09-d32, dt20-d258 low consumption ?blelfl???ml?ul??? d09?d150 ? bd ed fd ? gd ? md ? ud rd ? ? f115-f330 ? bd ed fd ? gd ? md ? ud rd ? ? f400?f780 ? ? ed fd ? gd ? md ? ud rd ? ? e not available for lc1d80 - lc1d150 f not available for lc1d115 or lc1d150 g not available for lc1f780. the 600 v coils for the lc1f400 - lc1f630 do not include an auxiliary contact for holding circuits. h for additional voltage codes refer to the iec contactor and starter catalog 8502ct9901 . i for use with f265?f330 only. table 18.7: coil voltage codes for ac and dc volt ages for f800 (includes built-in surge suppressor) volts ac/dc 24 48 110 120 127 208 220 240 277 380 415 440 480 575 600 660 50/60 hz ? ? fw fw fw ? mw mw ? qw qw qw ? ? ? ? i12 discount schedule
www.schneider-electric.us 18 iec contactors and starters 18-6 ? 2009 schneider electric all rights reserved contactors tesys ? d 3- and 4-pole reversing, ac or dc operating coil refer to catalog 8502ct9901 each 3-pole device is pre-wired with line and l oad side power wiring for reversing applications. each 4-pole device is pre-wir ed with load side power wiring tesys d contactor accessories . . . . . . . . . . . . . . . . . . . . pages 18-8 to 18-11 tesys d overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 tesys d replacement coils. . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19 dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 lc2d09 e164862 ccn nldx lr43364 class 3211 04 table 18.8: 3-pole & 4-pole mechanically interlocked contactors maximum horsepower ratings maximum current no. of n.o. power poles built in auxiliary contacts (per contactor) catalog number ab $ price single phase three phase inductive ac3 amperes resistive ac1 amperes ac control dc control 115 v hp 230 v hp 200 v hp 230 v hp 460 v hp 575 v hp n.o. n.c. 0.512257.59 20 3 1 1 lc2d09 c 234.00 317.00 ?????? ? 411lc2dt20 234.00 317.00 12337.51012 25 3 1 1 lc2d12 c 317.00 368.00 ?????? ? 411lc2dt25 317.00 368.00 1355101518 35 311lc2d18 c 344.00 400.00 ?????? ? 32 411lc2dt32 419.00 443.00 2 3 7.5 7.5 15 20 25 40 3 1 1 lc2d25 c 374.00 436.00 ?????? ? 411lc2dt40 456.00 477.00 2 5 10 10 20 30 32 50 3 1 1 lc2d32 c 415.00 503.00 3 5 10 10 30 30 40 60 3 1 1 lc2d40a 565.00 650.00 3 7.5 15 15 40 40 50 70 3 1 1 lc2d50a 596.00 680.00 5 1020205050 65 80 311lc2d65a 778.00 857.00 7.5 15 30 30 60 60 80 125 311 d ? ?????? ? 4?? d ? ? ? 30 40 75 100 115 200 311lc2d115 e 1165.00 1165.00 ?????? ? 4??lc2d115004 e 1391.00 1391.00 ? ? 40 50 100 125 150 200 3 1 1 lc2d150 e 1598.00 1598.00 a use voltage codes from the ?voltage codes? table below to complete the catalog number. for example: lc2d09g7 b includes mechanical interlock without electrical contacts. instal ler to complete wiring for electronically interlocking contact or operating coils by utilizing a n.c. auxiliary contact integrated in the contactor or optional ladn or lad8n auxiliary contact block. c for lc2d09?lc2d32, electrical interlock can be included by adding a ?v? to the end of the catalog number (ex: lc2do9b7v). list price adder: $5.00. d for these items, order two non-reversing contactors and one mechanical interlock separately. see page 18-4 and 18-14 for select ion. e includes mechanical interlock (type la9d11502) with pre-wired electrical contacts for interlocking contactor operating coils. table 18.9: coil voltage codes i contactor hz 24 v 48 v 110 v 120 v 125 v 208 v 220 v 240 v 250 v 440 v 480 v 600 v ac d09?d150 50/60 b7 e7 f7 g7 ? le7 m7 u7 ? ? t7 f x7 f lc1d80?lc1d150 50 b5 e5 f5 ? ? ? m5 f u5???? 60 b6 e6 f6 g6 ? l6 m6 u6 ? ? t6 x6 gf f115, f150, f185 50 hzb5e5f5???m5u5???? 60 hz b6 e6 f6 g6 ? l6 m6 u6 ? ? q5 sc f265, f330 40?400 hz b7 e7 f7 g7 ? l7 m7 u7 ? ? s7 j x7 f400?f780 40?400 hz ? e7 f7 f7 ? l7 m7 u7 ? ? n7 x7 h dc d09-d32, dt20-d258 low consumption ?blelfl???ml?ul??? d09?d150 ? bd ed fd ? gd ? md ? ud rd ? ? f115?f330 ? bd ed fd ? gd ? md ? ud rd ? ? f400?f780 ? ? ed fd ? gd ? md ? ud rd ? ? f not available for lc1d80 - lc1d150. g not available for lc1d115 or lc1d150. h not available for lc1f780. the 600 v coils for the lc1f400 - lc1f630 do not include an auxiliary contact for holding circuits. i for additional voltage codes refer to the iec contactor and starter catalog 8502ct9901 . j for use with f265?f330 only. table 18.10: coil voltage codes for ac and dc coil voltages for f800 (includes built-in surge suppressor) volts ac/dc 24 48 110 120 127 208 220 240 277 380 415 440 480 575 600 660 50/60 hz ? ? fw fw fw ? mw mw ? qw qw qw ? ? ? ? i12 discount schedule
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-7 contactors tesys ? f 3-pole reversing, ac or dc operating coil refer to catalog 8502ct9901 how to order: components are available for customer assemb ly of tesys f reversing contactors. for example, the following components must be ordered to build a 75 hp @ 460 v reversing contactor with a 120 v/60 hz coil: tesys f contactor accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-11 tesys f overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . . page 18-16 tesys f replacement coils and parts . . . . . . . . . . pages 18-13, 18-18, 18-20 dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-42 table 18.11: quantity catalog number description 2 lc1f115g6 contactors 6 dz2ff1 lugs (page 18-12) 2 ladn11 auxiliary contacts 1 la9ff976 power connections 1 la9ff970 mechanical interlock table 18.12: 3-pole contactors maximum horsepower ratings ma ximum current holding circuit contact built into coil catalog number a $ price three phase inductive ac3 amperes resistive ac1 amperes 200 v hp 230 v hp 460 v hp 575 v hp n.o. n.c. 30 40 75 100 115 200 1 0 lc1f115 479.00 40 50 100 125 150 250 1 0 lc1f150 696.00 50 60 125 150 185 275 1 0 lc1f185 938.00 60 75 150 200 265 350 1 0 lc1f265 1179.00 75 100 200 250 330 400 1 0 lc1f330 1621.00 100 125 250 300 400 500 1 0 lc1f400 1874.00 150 200 400 500 500 700 1 0 lc1f500 4970.00 250 300 600 800 630 1000 1 0 lc1f630 6872.00 current rated 780 1600 0 0 lc1f780 7788.00 ? 450 800 900 800 1000 0 0 lc1f800 6676.00 a use coil voltage codes from the ?voltage codes? table on page 18-6 to complete the contactor catalog number. table 18.13: auxiliary contact (electrical interlocking) - 2 must be purchased for use with number of contacts maximum number of blocks per contactor contact arrangement catalog number $ price lc1f to be ordered separately 11 1? ladn10 13.10 ?1 ladn01 13.10 22 11 ladn11 20.70 2- ladn20 20.70 42 22 ladn22 41.50 13 ladn13 41.50 4? ladn40 41.50 ?4 ladn04 41.50 31 ladn31 41.50 22 b ladc22 41.50 b including 1 n.o. + 1 n.c. make-before-break table 18.14: accessories ? for the assembly of three- pole reversing contactors (horizontal mounting) with 2 identical contactors c set of power connections catalog number $ price horizontal mounting mechanical interlock kit catalog number $ price lc1f115 la9ff976 106.00 la9ff970 53.00 lc1f150 la9f15076 96.00 la9ff970 53.00 lc1f185 la9fg976 113.00 la9fg970 53.00 lc1f265 la9fh976 151.00 la9fj970 76.00 lc1f330 la9fj976 225.00 la9fj970 76.00 lc1f400 la9fj976 198.00 la9fj970 76.00 lc1f500 la9fk976 306.00 la9fj970 76.00 lc1f630, f800 la9fl976 568.00 la9fl970 76.00 c for two contactors of different size, refer to pages 18-15. lc1f265 e164862 ccn nldx lr43364 class 3211 04 i12 discount schedule
www.schneider-electric.us 18 iec contactors and starters 18-8 ? 2009 schneider electric all rights reserved contactor accessories tesys ? d & f auxiliary contacts, time delay, mechanical latch refer to catalog 8502ct9901 tesys d contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-4, 18-6 tesys d overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 tesys d replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-18 to 18-19 dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 table 18.15: standard, instantaneous auxiliary contact blocks snap-on mounting number of contacts composition catalog number a $ price n.o. n.c. to front of lc dt20?d258 (4p), lc d09?d150 a or to right side of lc f 4 a 22 ladn22 b 41.50 13 ladn13 b 41.50 40 ladn40 b 41.50 04 ladn04 b 41.50 31 ladn31 b 41.50 2 c 2 c ladc22 bc 41.50 2 11 ladn11 b 20.70 20 ladn20 b 20.70 02 ladn02 b 20.70 to front of lc d80 and d115 or to left side of lc f 1 10 ladn10 d 13.10 01 ladn01 d 13.10 to side of lc d09 to d150 only (not for use on tesys f) 211 lad8n11 e 20.70 20 lad8n20 e 20.70 a for low consumption coils (lc1d09 to d32 only), only one front-mounted two-contact block allowed. no side- mounted contact blocks allowed. b for spring terminal versions of these blocks, add a ?3? to the end of the catalog number. (ex. ladn223). no price adder for this modification. c including 1 n.o. + 1 n.c. make before break overlapping contacts. d this block cannot be added to the lc1d 09 to d32 contactors; a maximum of 2 blocks can be mounted on the lc1d40a to lc1/lp1d80 contactors only. e 1 block may be added to the left side of the lc1d 09 to d32, ac coils only; 1 block may be added to each side of the lc1d 40a to d80 contactors, ac coils only. cannot be installed on tesys d contactors with dc coils. table 18.16: instantaneous blocks with dust-tight auxiliary contacts (ip54) nema 12 snap-on mounting standard contacts dusttight contacts catalog number $ price n.o. n.c. n.o. n.c. to front of lp d40?d80, lc dt20?d258 (4p), lc d09 to d80 or to right side of lc f ?? 2 ? la1dx20 65.00 2?2? la1dz40 82.00 112? la1dz31 82.00 ?? 2 ? la1dy20 f 77.00 f device supplied with 4 ground terminal points. table 18.17: pneumatic time delay contact blocks snap-on mounting time delay contacts type range of time delay catalog number h $ price n.o. n.c. to front of lp d40?d80, lc dt20?d258 (4p), lc d09 to d150 or to right side of lc f 11 on energization (on delay) 0.1 to 3 s g ladt0 131.00 0.1 to 30 s ladt2 131.00 10 to 180 s ladt4 131.00 1 to 30 s i lads2 131.00 11 on de-energization (off-delay) 0.1 to 3 s g ladr0 131.00 0.1 to 30 s ladr2 131.00 10 to 180 s ladr4 131.00 g scale range is expanded between 0.1 and 0.6 seconds on the dial for more accurate settings at the lower end of the range. h for spring terminal versions of these blocks, add a ?3? to the end of the catalog number. (ex. ladt23). no price adder for this modification. i with switching time of 40 ms 15 ms between the opening of the n.c. contact to the closing of the n.o. contact. table 18.18: mechanical latch blocks with manual or electrical unlatch (tesys d only) front snap-on mounting onto application catalog number to be completed by the code corresponding to the coil voltage $ price lc d09 to d65a for silent operation and energy conservation lad6k10 jk 77.00 lc1 d80 to d150 lp1 d80 for silent operation and energy conservation la6dk20 jk 77.00 j does not include internal coil clearing contact. k complete catalog number by adding coil voltage code. for example: lad6k10f. table 18.19: coil voltage codes for la6dk mechanical latch blocks volts 12 24 32/36 42/48 60/72 100 110/ 127 200/ 208 220/ 240 380/ 415 440/ 480 500/ 600 ac or dc j b c e en k f l m q r s front mounted auxiliary blocks (shown on tesys d contactor) e164862 ccn nldx lr43364 class 3211 04 i12 discount schedule
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-9 contactor accessories tesys ? d coil suppressors, cabling accessories refer to catalog 8502ct9901 rc coil suppressor ? limitation of transient voltage to 300% of nominal voltage maximum ? oscillating frequency limited to 400 hz maximum. slight increase in drop-out time (1.2 to 2 times normal) varistor coil suppressor ? limitation of transient voltage value to 200% of nominal voltage maximum ? maximum reduction of transient voltage peaks. slight increase in drop-out time (1.1 to 1.5 times normal) diode coil suppressor ? no overvoltage or oscillating frequency ? polarized component. increased drop-out time (6 to 10 times normal) bidirectional diode coil suppressor ? protection provided by limiting the transient voltage to 2 uc max. ? maximum reduction of transient voltage peaks tesys d contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6 tesys d overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . .page 18-16 tesys d replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-18 to 18-19 dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 table 18.20: resistor/capacitor circuit (rc) for reduction of ?electrical noise? in ac contactor coils installed by mounting on operating volt age 50/60 hz catalog number $ price snapping into cavity on right side without tools b lc1d09 to lc1d32 (3p) lc dt20 to dt40 (4p), 24?28 v lad4rce 26.20 50?127 v lad4rcg 26.20 110?240 v lad4rcu 26.20 snap-on mounting and connection without tools to the contactor coil terminals lc1d40a to lc1d65a (3p), lc1dt60a to lc1dt80a (4p) 24-48 v lad4rc3e 26.20 50-127 v lad4rc3g 26.20 110-240 v lad4rc3u 26.20 380-415 v lad4rc3n 26.20 screw connection to the contactor coil terminals lc d80 to d150 (3 or 4p) lc d80 to d115 (4p) 24?48 v la4da2e 26.20 50?127 v la4da2g 26.20 110?240 v la4da2u 26.20 380?415 v la4da2n 26.20 table 18.21: varistor (peak limiting) for reduction of ?electrical noise? in ac or dc contactor coils installed by mounting on operating volt age 50/60 hz catalog number $ price snapping into cavity on right side without tools b lc d09 to d32 a tesys d contactors 24?48 v lad4ve 26.20 50?127 v lad4vg 26.20 110?250 v lad4vu 26.20 snap-on mounting and connection without tools to the contactor coil terminals lc1d40a to lc1d65a (3p), lc1dt60a to lc1dt80a (4p) 24-48 v lad4v3e 26.20 50-127 v lad4v3g 26.20 110-250 v lad4v3u 26.20 screw connection to the contactor coil terminals lc d80 to d115 (3p or 4p) lc d12, d25 (4p) 24?48 vac la4de2e 26.20 50?127 vac la4de2g 26.20 110?250 vac la4de2u 26.20 screw connection to the contactor coil terminals lc d80 (3p or 4p) 24?48 vdc la4de3e 26.20 50?127 vdc la4de3g 26.20 110?250 vdc la4de3u 26.20 a for dc coils 3-pole contactors are fitted with built-in surge suppression as standard. table 18.22: diode for reduction of ?electrical noise? in dc contactor coils installed on the upper part by mounting on operating voltage dc catalog number $ price snap-on mounting and connection w/o tools to the contactor coil terminals lc d09 - d32 24?250 v lad4ddl 26.20 clip-on front mounting lc d40a to d65, d65a to dt80a 24?250 v lad4d3u 26.20 screw connection of wire to the contactor coil terminals d80 (3p) d80 (4p) 24?250 v la4dc3u 26.20 table 18.23: bidirectional peak limiting diode installed by mounting on operating voltage 50/60 hz and dc catalog number $ price snapping into cavity on right side of contactor b lc d09 to lc d32 (3p) c dt20 to dt40 (4p) 24 (ac only) lad4tb 26.20 72 (ac only) lad4ts 26.20 clip-on front mounting and connection without tools to the contactor coil terminals c lc1d40a to lc1d65a (3p), lc1dt60a to lc1dt80a (4p) 12 - 24 v lad4t3b 26.20 25 - 72 v lad4t3s 26.20 73 - 125 v lad4t3g 26.20 126 - 250 v lad4t3u 26.20 251 - 440 v lad4t3r 26.20 screw mounting d lc d80 24 (ac only) la4db2b 56.00 72 (ac only) la4db2s 26.20 24 (dc only) la4db3b 56.00 72 (dc only) la4db3s 56.00 b installing suppressor into the cavity ma kes the electrical connection. overall width of contactor remains the same. c for lc d09 through lc d65a with dc or low consumption dc coils, 3-pole contactors are fitted with built-in bidirectional diode suppression as standard. d mounting at the top of the contactor on coil terminals a1 and a2. table 18.24: cabling accessories usage mounting on operating voltage 50/60 hz catalog number $ price for adapting existing wiring to a new product or for use with top mount accessory. lc1d09 to d38 lc1dt20 to dt60 ac only without coil suppression lad4bb 23.00 with coil suppression (varistor) 24-48 v lad4bbve 23.00 50-127 v lad4bbvg 23.00 110-250 v lad4bbvu 23.00 for adapting existing wiring to a new product or for use with top mount accessory lc1d40a to lc1d65a (with no coil suppressor) ? lad4bb3 26.20 la4da1u la4da2u la4dc3u lad4bb? ? i12 discount schedule
www.schneider-electric.us 18 iec contactors and starters 18-10 ? 2009 schneider electric all rights reserved the following accessories require use of cabling accessories (lad4bb ) for proper mounting. see page 18-9 for illustration. electronic serial timer modules these solid state modules delay the energiz ing and de-energizing of the contactor coil. interface modules b these modules allow the contactor coils to be energized fr om low voltage and low current level signals. they come in mechanical relay and solid state versions. the relay plus manual operation versions include a lever for manually turning the contactor on and off. when a module receives a lo w level signal, it allows t he separate sourced control voltage to flow to the contactor coil. it saves space and wiring time compared to conv entional interposing relays. b adapter required for d09 - d65a, see table 18.24. automatic-manual-stop control modules these modules allow for local and/or remote operation of t he contactor coil. each module includes a lever to switch from automatic to manual operation and a dial to turn the contactor on and off. low voltage ride through module (meets semi f47 requirements) by ensuring semi f47 compliance of ac powered iec contac tors and relays, the low voltage ride through modules can be used to increase the voltage sag immunity of se miconductor processing equipment. these modules make it possible for ac powered telemecanique contactors and relays to exceed the requirements of semi f47, both in the magnitude and duration of a voltage sag event?even with ac cessories such as auxiliary contact blocks and pneumatic timers. the low voltage ride through modules can be used with tele mecanique contactors from 9 a through 80 a, as well as the cad series of control relays tesys d contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-4, 18-6 tesys d overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 tesys d replacement coils. . . . . . . . . . . . . . . . . . . . . . . pages 18-18 to 18-19 dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 table 18.25: type operational voltage a time delay catalog number $ price 24?250 vac 100?250 vac on-delay lc1d09?d65a lc1d80?d150 0.1?2 s la4dt0u 82. 1.5?30 s la4dt2u 82. 25?500 s la4dt4u 82. a for 24 v operation, the contactor must be fitted with a 21 v coil: coil voltage code z5 for 50 hz; z6 for 60 hz; zd for dc. table 18.26: interface type operational voltage input voltage catalog number $ price 24?250 vac 100?250 vac relay lc1d09?d150 24 vdc la4dfb 55. lc1d09?d150 48 vdc la4dfe 55. relay plus lc1d09?d150 24 vdc la4dlb 71. manual operation lc1d09?d150 48 vdc la4dle 71. solid state lc1d09?d65 lc1d80?d115 24 vdc la4dwb 71. la4dfb table 18.27: operational voltage catalog number $ price 24?100 vac 100?250 vac lc1d09?d150 ? la4dmk 35. table 18.28: for use on: catalog number $ price contactor relay lc1d b7 cad b7 ladlvrt24v c 124. lc1d g7 cad g7 ladlvrt120v c 124. lc1d le7 cad le7 ladlvrt208v c 124. top mount bracket ( required when using above modules) d09 - d32 lad4bb c 23. top mount bracket ( required when using above modules) d40 - d65 lad4bb3 c 23. fuse la9d941 120. c lad4bb must be used when the low voltage ride through module is being used with contactors 32 a and less, and tesys cad series of control relays. the lad4bb3 must be used with the d40 - d65a. see table 18.24 on page 18-10. e2 e1 a2 a2 a1 a1 1.25 32 ladlvrt 1.85 47 lad4bb e1 e2 a1 a2 ladlvrt contactors 40 a?80 a contactors 32 a and less contactor accessories tesys ? d electronic timers and interface modules refer to catalog 8502ct9901 i12 discount schedule
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-11 contactor accessories tesys ? d and f accessories refer to catalog 8502ct9901 tesys d contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6 tesys d overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . .page 18-16 tesys d replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-18 to 18-19 dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-47 tesys f contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-5, 18-7 tesys f replacement coils and parts . . . . . . . . . . pages 18-13, 18-18, 18-20 table 18.29: for power pole or control connection description for use with contactors lc1/lp1 sold in lots of catalog number $ price each connectors for larger cable sizes 4 poles #8 awg (10 mm 2 )d09, d12 1 lad92560 8.70 3 poles #4 awg (25 mm 2 ) d09?d32 1 la9d3260 12.00 everlink? terminal block 3 poles d40a-d65a 1 lad96560 10.00 links for the parallel connection of 2 poles d09?d32 10 la9d2561 26.20 d40a?d65a 1 lad9p32 6.00 d80 2 la9d80961 6.50 f115 4 la9ff602 55.00 f150, f185 4 la9fg602 65.00 f265, f330, f400 4 la9fh602 169.00 f500 4 la9fk602 228.00 f630, f800 4 la9fl602 278.00 3 poles (wye-delta shorting strap) d09?d32 10 lad9p3 10.00 d40a-d65a 1 lad9p33 25.00 d80 1 la9d80962 6.50 f115 1 la9ff601 6.80 f150, f185 1 la9fg601 8.20 f265, f330, f400 1 la9fh601 12.00 f500 1 la9fk601 21.80 f630, f800 1 la9fl601 38.20 4 poles dt20, dt25 2 la9d1263 8.70 d80 2 la9d80963 17.50 second coil connection lp1d40?d80 10 la9d09966 2.20 control circuit take-off from main pole d115, d150 10 la9d11567 4.00 d80 10 la9d8067 5.50 spreaders for increasing pole pitch to 45 mm d115, d150 3 gv7ac03 31.10 table 18.30: for marking description for use with contactors lc1/lp1 sold in lots of catalog number $ price each reference label holder snap-on 8 x 22 mm 4-pole contactors d80 - d115 100 la9d92 .06 reference label holder sn ap-on 8 x 18 mm 3 poles d09-d65a, dt20-dt80a, ladn, ladt, ladr 100 lad90 .06 sheet of 300 labels self adhesive 7 x 21 mm for holder la9d92 1 la9d93 4.30 table 18.31: for mounting description for use with contactors lc1/lp1 sold in lots of catalog number $ price each set of shims for mounting lad8n and la8dn d80 1 la9d511 9.80 retrofit plate for replacement of lc1d40-d65 with lc1d40a-d65a d40a-d65a 1 lad7x3 25.00 35 mm din rail ? 2 meters long lc1d09 to d80 10 am1dp200 5.20 table 18.32: replacement contacts for use with contactors catalog number $ price three-pole lc1d115 3 poles la5d1158031 239.00 lc1d150 3 poles la5d150803 239.00 four-pole lc1d115 4 poles la5d115804 318.00 table 18.33: arc chambers for use with contactors catalog number $ price three-pole lc1d115 3 poles la5d11550 90.00 lc1d150 3 poles la5d15050 90.00 four-pole lc1d115 4 poles la5d115450 119.00 la9d1260 la9d2561 la9d40961 la9d6567 la9d511 i12 discount schedule
www.schneider-electric.us 18 iec contactors and starters 18-12 ? 2009 schneider electric all rights reserved contactor accessories tesys ? f contactors refer to catalog 8502ct9901 these clear plastic protective shrouds are an effective means to meet international touch-safe requirements for power terminals. they are designed to be used with pow er cables that have been bolted to the terminal. note: the protection shrouds do not attach to contactors or ov erloads utilizing dz2f lug kits. for contactors lc1f115, lc1f150, and lc1f185, an available t ouch-safe terminal block ma y be used in place of lugs for power connections. tesys f contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-5, 18-7 tesys f overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 tesys f replacement coils and parts . . . . . . . . . .pages 18-18, 18-18, 18-20 dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-47 la9d09981 la9f980 table 18.34: suppressor blocks operating limit: up to 220 v, 50/60 hz coils description for use catalog number $ price suppressor block (clip-on mounting to coil) with coils lx1ff, fg, fh, f115, f150, f185, f225, f265, f330 la9f980 21.80 with coils lx1fj, fk, fl, fx, f400, f5 00, f630, f780, lx9ff, fg, fh, f115, f150, f185, f225, f265, f330 la9d09980 20.70 mounting bracket (for 35 mm din rail or panel mounting) for suppressor block la9d09981 5.50 table 18.35: lugs and lug kits a contactor type lc1 lug kit catalog number contactor only cable size awg range overload relay directly mounted to contactor lugs required cable size awg range lc1 ? line side of contactor load side of overload line side of contactor load side of overload f115 dz2ff6 14 to 2/0 lr9f5 ? 57 to f5 ? 69 f115 3 each dz2ff1 3 each dz2fg1 14 to 2/0 6 to 3/0 f150, f185 dz2fg6 6 to 3/0 lr9f5 ? 57 to f5 ? 71 f150 to f185 1 each dz2fg6 6 to 3/0 ?lr9f5 ? 71 f225, f265 1 each dz2fh6 6 to 300 mcm f225, f265, f330 dz2fh6 6 to 300 mcm lr9f7 ? 75 to f7 ? 79 f265 or f330 3 each dz2fh1 6 to 300 mcm 4 to 500 mcm f400 dz2fj6 4 to 500 mcm lr9f7 ? 75 to f7 ? 81 f400 3 each dz2fj1 4 to 500 mcm 4 to 500 mcm f500 dz2fk6 2 x 2 to 600 mcm lr9f7 ? 75 to f7 ? 81 f500 3 each dz2fk1 2x2 to 600 mcm 4 to 500 mcm f630, f800 dz2fl6 3 x 2 to 600 mcm lr9f7 ? 81 f630 1 each dz2fl1 dz2fl2 dz2fl3 1 each dz2fr1 3x2 to 600 mcm 4 to 500 mcm f780 dz2fx6 4 x 1/0 to 750 mcm ? ? ? ? a lug kits ending in the number ?6? include 6 identical lugs. in some cases the lr9f overload relay mounted directly on the load side of an lc1f contactor will require a different size lug for your choice of contactor and overload. if the two sizes are different, order 3 of each si ze lug. mounting hardware (screws, washers, and nuts) are provided with the contactors and overload relays, not with the lugs. see table 18.37 for pricing. table 18.36: lugs?2 and 4-pole c contactor type lc1 lug kit catalog number qty. required al/cu cable size 2-pole 4-pole f115 dz2ff1 4 8 14 to 2/0 f150, f185 dz2fg1 4 8 6 to 3/0 f225, f265, f330 dz2fh1 4 8 6 to 300 mcm f400 dz2fj1 4 8 4 to 500 mcm f500 dz2fk1 4 8 2 x 2 to 600 mcm f630 dz2fl b bb 3 x 2 to 600 mcm f780 dz2fx1 4 8 4 x 1/0 to 750 mcm b for 2-pole f630 contactors, order 2 dz2fl1 (l1 and t2), and 2 dz2fl3 (l2 and t1). for 4-pole f6304, order 2 dz2fl1 (l1 and t4), 4 dz2fl2 (l2, t2, l3, t3) and 2 dz2fl3 (l4 and t1). c lugs for lc1f contactors and overload relays must be ordered s eparately. each kit consists of one (1) lug. mounting hardware (s crews, washers, nuts) are provided with the contactors, not the lugs. see table 18.37 for pricing. table 18.37: lugs pricing lug catalog number $ price lug catalog number $ price dz2ff6 39.30 dz2fh1 11.00 dz2fg6 65.00 dz2fj1 11.00 dz2fh6 65.00 dz2fk1 21.80 dz2fj6 65.00 dz2fl1 27.30 dz2fk6 131.00 dz2fl2 55.00 dz2fl6 164.00 dz2fl3 27.30 dz2fx6 163.80 dz2fr1 173.30 dz2ff1 6.50 dz2fx1 27.30 dz2fg1 11.00 la9f70 z table 18.38: power terminal protection shrouds for use with 2-, 3-, and 4-pole contactors number of shrouds per set catalog number $ price lc1f115 6 la9f701 42.40 lc1f150, f185 6 la9f702 61.00 lc1f225, f265, f330, f400 and f4002, f500 and f5002 6 la9f703 82.00 lc1f630, f6302 and f800 6 la9f704 93.00 lc1f1154 8 la9f706 58.00 lc1f1504 and f1854 8 la9f707 80.00 lc1f2254, f2654, f3304, f4004, f5004 8 la9f708 111.00 lc1f6304 8 la9f709 120.00 table 18.39: insulated terminal blocks for contactor type lc1 for overload relay lr9 maximum cable size catalog number $ price f115, f150, f185 f5 ? 57, f5 ? 63, f5 ? 67, f5 ? 69 300 mcm la9f103 55.00 i12 discount schedule
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-13 replacement parts tesys ? f contact kits, arc chambers refer to catalog 8502ct9901 tesys f contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-5, 18-7 tesys f overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . .page 18-16 tesys f replacement coils and parts . . . . . . . . . . pages 18-13, 18-18, 18-20 dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-42 to 18-47 la5fg431 la5f11550 table 18.40: replacement contact sets a for use on contactors catalog number $ price two-pole lc1f4002 2 poles la5f400802 717. lc1f5002 2 poles la5f500802 1111. lc1f6302 2 poles la5f630802 1651. three-pole lc1f115, f150 3 poles la5ff431 239. lc1f185 3 poles la5fg431 418. lc1f265 3 poles la5fh431 793. lc1f330, f400 3 poles la5f400803 1076. lc1f500 3 poles la5f500803 1589. lc1f630 3 poles la5f630803 2488. lc1f780 1 pole la5f780801 d 1651. lc1f800 3 poles la5f800803 2488. four-pole lc1f1504, f1154 4 poles la5ff441 318. lc1f1854 4 poles la5fg441 549. lc1f2654 4 poles la5fh441 966. lc1f3304, f400, f4004 4 poles la5f400804 1435. lc1f5004 4 poles la5f500804 2461. lc1f6304 4 poles la5f630804 3304. lc1f7804 1 pole la5f780801 d 1651. table 18.41: arc chambers for use on contactors catalog number $ price two-pole lc1f4002 2 poles la5f400250 280. lc1f5002 2 poles la5f500250 305. lc1f6302 2 poles la5f630250 431. three-pole lc1f115 3 poles la5f11550 90. lc1f150 3 poles la5f15050 101. lc1f185 3 poles la5f18550 179. lc1f265 3 poles la5f26550 269. lc1f330 3 poles la5f33050 287. lc1f400 3 poles la5f40050 305. lc1f500 3 poles la5f50050 341. lc1f630 3 poles la5f63050 646. lc1f780 1 pole la5f780150 d 431. lc1f800 3 poles la5f80050 750. four-pole lc1f1154 4 poles la5f115450 119. lc1f1504 4 poles la5f150450 131. lc1f1854 4 poles la5f185450 248. lc1f2654 4 poles la5f265450 299. lc1f3304 4 poles la5f330450 414. lc1f4004 4 poles la5f400450 c 573. lc1f5004 4 poles la5f500450 c 610. lc1f6304 4 poles la5f630450 b 861. lc1f7804 1 pole la5f780150 d 431. a supplied per pole are: 2 fixed contacts, 1 moving contact, 2 deflectors, 1 backplate, mounting screws and washers. b comprises single-pole components. c comprises 2-pole components. d 2 identical components per pole are supplied. i12 discount schedule
www.schneider-electric.us 18 iec contactors and starters 18-14 ? 2009 schneider electric all rights reserved contactors accessories tesys ? d reversing contactors refer to catalog 8502ct9901 tesys d contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-4, 18-6 tesys d overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 tesys d replacement coils. . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19 dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 table 18.42: contactors mechanical interlock set of power connections reversing contactors comprising two identical, horizontally mounted contactors: without electrical interlock with incorporated electrical interlock (2 n.c. contacts) reversing contactors for motor control four pole contactors catalog number $ price catalog number $ price catalog number $ price catalog number $ price lc1d09, lc1d12, lc1d18, lc1d25, lc1d32 lad9r1 e 32.10 lad9r1v e 45.50 included with kit not available lc1dt20, lc1dt25, lc1dt32, lc1dt40 ladt9r1 e 36.90 ladt9r1v e 45.50 not available included with kit e kit including mechanical interlock and wiring. lc1d40, lc1d50, lc1d/lp1d65 la9d50978 31.70 la9d4002 45.90 la9d6569 53.00 la9d6570 63.00 lc1d40a, d50a, d65a lad4cm 45.00 not available la9d65a69 75.00 not available lc1d80 ac coil la9d50978 31.70 la9d4002 45.90 la9d8069 65.00 la9d8070 79.00 lc1d80 dc coil la9d80978 31.70 la9d8002 65.00 la9d8069 65.00 la9d8070 79.00 lc1d115 and lc1d150 not available la9d11502 78.00 la9d11569 129.00 la9d11571 (3p) 53.00 la9d11570 (4p) (d115 only) 53.00 i12 discount schedule
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-15 contactors accessories tesys ? f reversing contactors refer to catalog 8502ct9901 tesys f contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-5, 18-7 tesys f overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . . page 18-16 tesys f replacement coils and parts . . . . . . . . . . . . . . .pages 18-18 to 18-20 dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-42 to 18-47 table 18.43: component parts for the assembly of f-line 3-pole reversing contactors with 2 identical contactors a set of power connections catalog number $ price mechanical interlock kit catalog number $ price horizontal mounting lc1f115 la9ff976 106.00 la9ff970 53.00 lc1f150 la9f15076 96.00 la9ff970 53.00 lc1f185 la9fg976 113.00 la9fg970 53.00 lc1f265 la9fh976 151.00 la9fj970 76.00 lc1f330 la9fj976 225.00 la9fj970 76.00 lc1f400 la9fj976 225.00 la9fj970 76.00 lc1f500 la9fk976 306.00 la9fj970 76.00 lc1f630 or f800 la9fl976 568.00 la9fl970 76.00 vertical mounting lc1f115 or f150 d ? la9ff4f 97.00 lc1f185 d ? la9fg4g 113.00 lc1f265 d ? la9fh4h 126.00 lc1f330 d ? la9fj4j 149.00 lc1f400 d ? la9fj4j 149.00 lc1f500 d ? la9fk4k 149.00 lc1f630 or f800 d ? la9fl4l 149.00 lc1f780 b ? la9fx970 b 508.00 table 18.44: component parts for the assembl y of tesys f 3-pole or 4-pole transfer contactors horizontal mounting set of power connections $ price mechanical interlock kit catalog number $ price three-pole four-pole lc1f115/4 la9ff982 la9ff977 53.00 la9ff970 53.00 lc1f150/4 la9f15082 la9f15077 53.00 la9ff970 53.00 lc1f185/4 la9fg982 la9fg977 53.00 la9fg970 53.00 lc1f265/4 la9fh982 la9fh977 83.00 la9fj970 76.00 lc1f330/4 la9fj982 la9fj977 113.00 la9fj970 76.00 lc1f400/4 la9fj982 la9fj977 113.00 la9fj970 76.00 lc1f500/4 la9fk982 la9fk977 154.00 la9fj970 76.00 lc1f630/4 la9fl982 la9fl977 233.00 la9fl970 76.00 vertical mounting lc1f115/4 dd ? la9ff4f 97.00 lc1f185/4 dd ? la9fg4g 113.00 lc1f265/4 dd ? la9fh4h 149.00 lc1f330/4 dd ? la9fj4j 149.00 lc1f400/4 dd ? la9fj4j 149.00 lc1f500/4 dd ? la9fk4k 149.00 lc1f630/4 dd ? la9fl4l 149.00 lc1f780/4 bc ? la9fx970 c 508.00 table 18.45: vertical mounting of 2 contactors of different ratings a upper contactor lower contactor e mechanical interlock kit catalog number $ price lc1f185 or 1854 lc1f115/150 or 1154/1504 la9fg4f 113.00 lc1f265 or 2654 lc1f115/150 or 1154/1504 la9fh4f 126.00 lc1f330 or 3304 lc1f185/1854 or 265/265a la9fh4g 126.00 lc1f400 or 4004 lc1f115/150 or 1154/1504 la9fj4f 126.00 lc1f185 or 1854 la9fj4g 126.00 lc1f265/2654 or 330/330a la9fj4h 149.00 lc1f500 or 5004 lc1f115/150 or 1154/1504 la9fk4f 149.00 lc1f185 or 1854 la9fk4g 126.00 lc1f265/2654 or 330/330a la9fk4h 149.00 lc1f400 or 4004 la9fk4j 149.00 lc1f630, 6304 or lc1f800 lc1f115/150 or 1154/1504 la9fl4f 116.00 lc1f185 or 1854 la9fl4g 126.00 lc1f265/2654 or 330/330a la9fl4h 149.00 lc1f400 or 4004 la9fl4j 149.00 lc1f500 or 5004 la9fl4k 149.00 a with identical or diffe rent numbers of poles. b double mechanical interlock with 2 mechanical links and 3 power connection bars. c double mechanical interlock with 2 mechanical links and 4 power connection bars. d power connection to be assembled by the customer, except for contactors lc1f780 and f7804. e lower contactor must have equal or lower current rating. la9f?970 la9f?976 la9f?977 la9f?4? la9fx970 l1 l2 l3 a1 a2 a1 a2 13 5 135 2 46 246 uvw reversing (motors) application a1 a2 a1 a2 1n 1l2 2l1 2l3 1l3 1l1 2l2 2n 1 3 57 1 357 2 4 6 82468 l1 l2 l3 n transfer/changeover applications i12 discount schedule
www.schneider-electric.us 18 iec contactors and starters 18-16 ? 2009 schneider electric all rights reserved overload relays tesys ? d and f overload relay accessories refer to catalog 8502ct9901 tesys d overload relay accessories tesys f overload relay accessories these clear plastic protective shrouds are an effective means to meet inte rnational finger-safe requirements for power terminals. they are designed to be used with pow er cables that have been bolted to the terminal. note: the protection shrouds do not attach to contac tors or overloads uti lizing dz2f lug kits. main overload selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-2, 18-3 dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-45 to 18-47 tesys t. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 16-91 table 18.46: mounting kits and plates a description for use with overload relays: catalog number $ price separate mounting kits for mounting to 35 mm din rail or for panel mounting with screws lrd01?35 and lr3d01?35 lad7b10 8.70 lrd01?35 and lrd01?35 for ring tongue terminals lad7b106 8.70 lrd15 ?? lad7b105 10.40 lr2d15 ?? la7d1064 8.70 lr2d25 ?? la7d2064 13.10 lrd3 ??? , lr3d3 ??? , lr2d35 ?? la7d3064 17.50 mounting plates for screw mounting at 110 mm (4.3") centers lrd01?35, lr3d01?35, lr2d15 ?? dx1ap25 11.00 lr2d25 ?? dx1ap26 12.00 lrd3 ??? , lr3d3 ?? , lr2d35 ?? la7d902 16.40 a when using mounting plates, separate mounting kits are also required. table 18.47: accessories description for use with standard packaging catalog number $ price pre wiring kit allows direct connection of the n.c. contact of relay lrd01?d32 or lr3d01?d32 to the contactor lc1d09 through d18 10 lad7c1 8.70 lc1d25, d32 10 lad7c2 8.70 stop button locking device all relays except lrd01?d32, lr3d01?d32 and lr9d 10 la7d901 2.20 remote stop/tripping or electrical reset c lrd01-d32, lrd3, lr3d01-d32, lr3d3 1 lad703 b 43.70 all relays except lrd01?d32, lr3d01?d31 1 la7d03 b 43.70 reset by flexible cable 500 mm (19.6 in.) lrd01-d32, lrd3, lr3d3 1 lad7305 100.00 b part number to be completed by adding coil voltage code. for example: lad703f. la7d03 table 18.48: control circuit voltages for la7d03 and lad703 volts 12 24 48 110 220/230 380/400 415/440 ac 50/60 hz j d befmqn dc jbefm?? c the time that the la7d03 can remain energized depends on its rest time; 1 s pulse with 9 s rest time; 5 s pulse with 30 s rest time; 10 s pulse with 90 s rest time; maximum pulse duration of 20 s with rest time of 300 s. consumption on inrush and sealed: < 100 va d not available for lrd01-d32, lr3d01-d32. la7d901 la7f90? table 18.49: mounting plate for overload relay for use with relays catalog number $ price lr9f5 ? 57, f5 ? 63, f5 ? 67, f5 ? 69 and f5 ? 71 la7f901 27.30 lr9f7 ? 75, f7 ? 79 and f7 ? 81 la7f902 38.20 table 18.50: power terminal protection shrouds, single-pole for use with relays catalog number $ price lr9f5 ? 57 la9f701 42.40 lr9f5 ? 63, f5 t 67, f5 ? 69 la9f702 61.00 lr9f5 ? 71 la9f705 86.00 lr9f7 ? 75, f7 ? 79, f7 ? 81 la9f703 82.00 table 18.51: power terminal protection shrouds, 3-pole for use with relays catalog number $ price lr9f5 ? 57, f5 ? 63, f5 ? 67, f5 ? 69 la7f701 27.30 lr9f5 ? 71 la7f702 38.20 lr9f7 ? 75, f7 ? 79, f7 ? 81 la7f703 49.20 table 18.52: connection accessories (for mounting overload relays beneath reversing contactors) e application set of 3 bars catalog number $ price for relays for contactor lr9f5 ? 57, f5 ? 63, f5 ? 67, f5 ? 69 lc1f115 la7f401 19.70 lr9f5 ? 57, f5 t 63 lc1f150 and f185 la7f402 21.80 lr9f5 ? 71 lc1f265 la7f403 27.30 lr9f7 ? 75, f7 ?? 79 lc1f265...f400 la7f404 30.50 lr9f7 ? 81 lc1f400 la7f404 30.50 lr9f7 ? 75, f7 ? 79, f7 ? 81 lc1f500 la7f405 38.20 lr9f7 ? 81 lc1f630 la7f406 43.70 e mounting plate required. table 18.53: marking accessories description sold in units of: catalog number $ price marker holder, snap-in 100 la7d903 .03 each la9f70? la7f701 i12 discount schedule
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-17 contactors repair parts tesys ? d and old d2 ac coils refer to catalog 8502ct9901 tesys d contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6 tesys d overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . .page 18-16 tesys d replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19 dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 lx1d2 table 18.54: for lc1d09?d32, lc1dt20?40 (tesys d) contactors and cad relays rated nominal voltage catalog number 50/60 hz $ price 12 lxd1j7 26.20 21 a lxd1z7 24 lxd1b7 32 lxd1c7 36 lxd1cc7 42 lxd1d7 26.20 48 lxd1e7 60 lxd1ee7 100 lxd1k7 110 lxd1f7 115 lxd1fe7 26.20 120 lxd1g7 127 lxd1fc7 200 lxd1l7 208 lxd1le7 220/230 lxd1m7 26.20 230 lxd1p7 230/240 lxd1u7 277 lxd1w7 380/400 lxd1q7 400 lxd1v7 26.20 415 lxd1n7 440 lxd1r7 480 lxd1t7 575 lxd1sc7 600 lxd1x7 26.20 690 lxd1y7 specifications 50/60 hz average consumption - inrush (inductance .75) - sealed (inductance .3) 70 va 7 va operating range@ 60 o c 80?110% of nominal @ 50 hz, 85?110% of nominal @ 60 hz a voltage for special coils fitted in co ntactors with serial timer modules, with 24 v supply. table 18.55: for lc1d09, d12, d18?for old d2 style contactors where the catalog number includes the auxiliary contact arrangement rated nominal voltage v catalog number 50 hz catalog number 60 hz catalog number 50/60 hz $ price 21 b lx1d2z5 lx1d2z6 lx1d2z7 52.40 24 lx1d2b5 lx1d2b6 lx1d2b7 32 lx1d2c5 ?? 42 lx1d2d5 ? lx1d2d7 48 lx1d2e5 lx1d2e6 lx1d2e7 110 lx1d2f5 lx1d2f6 lx1d2f7 52.40 120 ? lx1d2g6 lx1d2g7 127 lx1d2g5 ?? 208 ? lx1d2l6 ? 220 lx1d2m5 lx1d2m6 lx1d2m7 230 lx1d2p5 ? lx1d2p7 52.40 240 lx1d2u5 lx1d2u6 lx1d2u7 256 lx1d2w5 ?? 277 ? lx1d2w6 ? 380 lx1d2q5 lx1d2q6 lx1d2q7 400 lx1d2v5 ? lx1d2v7 52.40 415 lx1d2n5 ? lx1d2n7 440 lx1d2r5 lx1d2r6 lx1d2r7 480 ? lx1d2t6 ? 500 lx1d2s5 ?? 575 ? lx1d2s6 ? 52.40 600 ? lx1d2x6 ? 660 lx1d2y5 ?? specifications average consumption inrush (inductance .75) 50 hz 60 hz 50/60 hz 60 va 70 va 70 va at 50 or 60 hz sealed (inductance .3) 7 va 7.5 va 8 va at 50 or 60 hz operating range at < 55 o c / 131 o f 80?110 % of nominal voltage 80?110% of nominal voltage 85?110% of nominal voltage table 18.56: for lc1d25, d32?for old d2 style contactors where the catalog number includes the auxiliary contact arrangement rated nominal voltage (v) catalog number 50 hz cata log number 60 hz catalog number 50/60 hz $ price 21 b lx1d4z5 lx1d4z6 lx1d4z7 72.00 24 lx1d4b5 lx1d4b6 lx1d4b7 32 lx1d4c5 ?? 42 lx1d4d5 ? lx1d4d7 48 lx1d4e5 lx1d4e6 lx1d4e7 110 lx1d4f5 lx1d4f6 lx1d4f7 72.00 120 ? lx1d4g6 lx1d4g7 127 lx1d4g5 ?? 208 ? lx1d4l6 ? 220 lx1d4m5 lx1d4m6 lx1d4m7 230 lx1d4p5 ? lx1d4p7 72.00 240 lx1d4u5 lx1d4u6 lx1d4u7 256 lx1d4w5 ?? 277 ? lx1d4w6 ? 380 lx1d4q5 lx1d4q6 lx1d4q7 400 lx1d4v5 ? lx1d4v7 72.00 415 lx1d4n5 ? lx1d4n7 440 lx1d4r5 lx1d4r6 lx1d4r7 480 ? lx1d4t6 ? 500 lx1d4s5 ?? 575 ? lx1d4s6 ? 72.00 600 ? lx1d4x6 ? 660 lx1d4y5 ?? specifications 50 hz 60 hz 50/60 hz average consumption - inrush (inductance .75) - sealed (inductance .3) 90 va 7.5 va 100 va 8.5 va 100 va at 50 or 60 hz 8.5 va at 50 or 60 hz operating range at < 55 o c / 131 o f 80?110% of nominal voltage 80?110% of nominal voltage 85?110% of nominal voltage b for use in 24 volt applications involving serial timer modules refer to page 18-10. i12 discount schedule l i m i t e d s t o c k w i l l b e r e p l a c e d w i t h t e s y s l i m i t e d s t o c k w i l l b e r e p l a c e d w i t h t e s y s
www.schneider-electric.us 18 iec contactors and starters 18-18 ? 2009 schneider electric all rights reserved contactors repair parts tesys ? d, old d2, and f ac coils refer to catalog 8502ct9901 c lc1f780 contactors operate on 2 coils as a set. the lx1fx part number includes both coils. d the 600 v coils for the f400, f500 and f630 do not include an auxiliary contact for holding circuits. if required, select appropriate contacts from page 18-8. e also requires rectifier dr5te4u for 110 v?240 v coils, dr5te4s for 380 v?440 v coils. see table below for pricing. f coil circuit requires a separately mounted rectifier. order from rectifier table. g complete catalog number by adding suffix. for example: lx1ff024. application note on contactor drop-out times: contactors using lx1, fh, fj, fk, fl, and fx coils have longer drop-out times. for critical applic ations such as emergency stop functions: ? select a fast drop-out coil (lx9), or ? use a maintained contact stop button, or ? use an interposing relay. tesys d contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6 tesys f contactors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-5, 18-7 tesys d overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-16 tesys d replacement coils. . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-17 to 18-19 dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-40 to 18-47 lx1d6 table 18.57: for old d2 style lc1d40, d50, d65, d80 table 18.58: for tesys d lc1d40a, d50a, d65a, dt60a, dt80a table 18.59: for tesys d lc1d115, d150 rated nominal voltage v catalog number 50 hz catalog number 60 hz catalog number 50/60 hz $ price rated nominal voltage v catalog number 50 hz catalog number 60 hz catalog number 50/60 hz $ price rated nominal volt ag e v catalog number 50 hz catalog number 60 hz catalog number 50/60 hz $ price 24 lx1d6b5 lx1d6b6 lx1d6b7 41.50 12 lxd3j5 ?? 41.50 24 lx1d8b5 lx1d8b6 lx1d8b7 78.00 32 lx1d6c5 ?? 41.50 24 ? ? lxd3b7 41.50 32 lx1d8c5 ? lx1d8c7 78.00 42 lx1d6d5 ? lx1d6d7 41.50 32 ? ? lxd3c7 41.50 42 lx1d8d5 ? lx1d8d7 78.00 48 lx1d6e5 lx1d6e6 lx1d6e7 41.50 42 ? ? lxd3d7 41.50 48 lx1d8e5 lx1d8e6 lx1d8e7 78.00 110 lx1d6f5 lx1d6f6 lx1d6f7 41.50 48 ? ? lxd3e7 41.50 110 lx1d8f5 lx1d8f6 lx1d8f7 78.00 120 ? lx1d6g6 lx1d6g7 41.50 100 ? ? lxd3k7 41.50 115 lx1d8fe5 ? lx1d8fe7 78.00 127 lx1d6g5 ?? 41.50 110 ? ? lxd3f7 41.50 120 ? lx1d8g6 lx1d8g7 78.00 208 ? lx1d6l6 lx1d6le7 41.50 115 ? ? lxd3fe7 41.50 127 lx1d8fc5 ? lx1d8fc7 78.00 220 lx1d6m5 lx1d6m6 lx1d6m7 41.50 120 ? ? lxd3g7 41.50 208 ? lx1d8l6 lx1d8l7 78.00 230 lx1d6p5 ? lx1d6p7 41.50 127 ? ? lxd3fc7 41.50 220/230 lx1d8m5 lx1d8m6 lx1d8m7 78.00 240 lx1d6u5 lx1d6u6 lx1d6u7 41.50 200 ? ? lxd3l7 41.50 230 lx1d8p5 ? lx1d8p7 78.00 256 lx1d6w5 ?? 170.00 208 ? ? lxd3le7 41.50 240 lx1d8u5 lx1d8u6 lx1d8u7 78.00 277 ? lx1d6w6 ? 41.50 220 ? ? lxd3m7 41.50 277 ? lx1d8w6 lx1d8w7 78.00 380 lx1d6q5 lx1d6q6 lx1d6q7 41.50 230 ? ? lxd3p7 41.50 380/400 lx1d8q5 lx1d8q6 lx1d8q7 78.00 400 lx1d6v5 ? lx1d6v7 41.50 240 ? ? lxd3u7 41.50 400 lx1d8v5 ? lx1d8v7 78.00 415 lx1d6n5 ? lx1d6n7 41.50 277 ? ? lxd3w7 41.50 415 lx1d8n5 ? lx1d8n7 78.00 440 lx1d6r5 lx1d6r6 lx1d6r7 41.50 380 ? ? lxd3q7 41.50 440 lx1d8r5 lx1d8r6 lx1d8r7 78.00 480 ? lx1d6t6 ? 41.50 400 ? ? lxd3v7 41.50 480 ? lx1d8t6 lx1d8t7 78.00 500 lx1d6s5 ?? 170.00 415 ? ? lxd3n7 41.50 500 lx1d8s5 ? lx1d8s6 78.00 575 ? lx1d6s6 ? 41.50 440 ? ? lxd3r7 41.50 for old style and new tesys style contactors where the catalog number may or may not include the auxiliary contact arrangement. 600 ? lx1d6x6 ? 41.50 480 ? ? lxd3t7 41.50 660 lx1d6y5 ?? 41.50 500 ? ? lxd3s7 41.50 for old style and new tesys style contactors where the catalog number may or may not include the auxiliary contact arrangement. 575 ? ? lxd3sc7 41.50 600 ? ? lxd3x7 41.50 660 ? ? lxd3yc7 41.50 690 ? ? lxd3y7 41.50 specification 50 hz 60 hz 50/60 hz specification 50 hz 60 hz 50/60 hz specification 50 hz 60 hz 50/60 hz average consumption: -inrush (inductance .75) -sealed (inductance .3) 200 va 20 va 220 va 22 va 245 va at 50 or 60 hz 26 va at 50 or 60 hz average consumption: -inrush (inductance .3) -sealed (inductance .3) 160 va 7.0 va 140 va 7.5 va 140 va (inductance: .9) 7.5 va (inductance: .9) average consumption: -inrush (inductance .3) -sealed (inductance .3) 300 va 22 va 300 va 22 va 350 va (inductance: .9) 18 va (inductance: .9) operating range at < 55 o c / 131 o f 80?110% of nominal voltage 80?110% of nominal voltage 85?110% of nominal voltage operating range at < 55 o c / 131 o f 85?110% of nominal voltage 85?110% of nominal voltage 80?115% of nominal voltage operating range at < 55 o c / 131 o f 85?110% of nominal voltage 85?110% of nominal voltage 80?115% of nominal voltage table 18.60: for lc1f115, f150, f185, f265, f330, f400, f500, f630, f780, f800 ? lx1 coils are the standard coils that are included when a voltage code is added to the contactor part number. the lx9 coils may be ordered separately for special applications. lx9 coils do not include a built-in normally open holding circuit contact; a separate auxiliary contact block wit h a n.o. contact should be added to the contactor. both the lx1 and lx9 coils can be used on the previous f-line contactors. device type hz catalog number catalog number suffix g 24 v 48 v 110 v 120 v 208 v 220 v 240 v 277 v 380 v 415 v 440 v 480 v 600 v $ price f115?f150 50 lx1ff ? 024 048 110 127 200 220 240 264 380 415 415 500 600 78.00 60 lx1ff ? 020 040 092 095 162 184 187 220 316 340 360 380 475 78.00 40?400 lx9ff ? ? 048 110 127 200 220 220 260 380 415 415 500 ? 78.00 f185 f225 50 lx1fg ? 024 048 110 127 200 220 240 264 380 415 415 450 600 108.00 60 lx1fg ? 020 040 092 095 162 184 187 220 316 340 360 380 475 108.00 40?400 lx9fg ? ? 048 110 127 200 220 220 260 380 415 415 500 ? 108.00 f265?f330 40?400 lx1fh ? 0242 0482 1102 1272 2002 2202 2402 2772 3802 3802 4402 5002 6002 138.00 40?400 lx9fh ? ? 0482 1102 1272 2002 2202 2402 2772 3802 3802 . . . 5002 ? 138.00 f400 d 40?400 lx1fj ? ? 048 110 110 200 220 240 280 380 415 415 415 600 287.00 40?400 lx9fj ? f 910 917 925 925 930 931 932 932 936 936 937 937 ? 287.00 f500 d 40?400 lx1fk ? ? 048 110 110 200 220 240 280 380 415 415 415 600 360.00 40?400 lx9fk ? f 910 917 925 925 930 931 932 932 936 936 937 937 ? 360.00 f630 d 40?400 lx1fl ? ? 048 110 110 200 220 240 260 380 415 415 415 600 398.00 40?400 lx9fl ? f 910 917 924 925 930 930 931 932 935 936 936 937 ? 483.00 f780, fx c 40?400 lx1fx ? ? ? 110 110 200 220 220 280 380 415 415 415 ? 795.00 f800 50/60 lx4f8 ? e ? ? fw fw ? mw mw ? qw qw qw ? ? 725.00 table 18.61: rectifier table coil rectifier catalog number $ price lx9f ? 910 dr5tf4v 75.00 lx9f ? 917 dr5tf4v 75.00 lx9f ? 925 dr5te4u 75.00 lx9f ? 926 dr5te4u 75.00 lx9f ? 931 dr5te4u 75.00 lx9f ? 936 dr5te4s 75.00 lx9f ? 937 dr5te4s 75.00 lx9f ? 938 dr5te4s 75.00 i12 discount schedule
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-19 contactors repair parts tesys ? d, and old d2 dc coils refer to catalog 8502ct9901 note: dc coils for lc1d09-d32, lc1dt20 - lc1dt40, and lcid tt a contactors are not replaceable. tesys d contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6 tesys d overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . .page 18-16 tesys d replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19 dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 table 18.62: for old d2 lp1d09, d12, d18 contactors ac rated nominal voltage v catalog number catalog number wide range $ price 12 lx4d2jd lx4d2jw 79.00 21 b lx4d2zd ? 79.00 24 lx4d2bd lx4d2bw 79.00 36 lx4d2cd lx4d2cw 79.00 48 lx4d2ed lx4d2ew 79.00 60 lx4d2nd ? 79.00 72 lx4d2sd lx4d2sw 79.00 110 lx4d2fd lx4d2fw 79.00 125 lx4d2gd ? 79.00 220 lx4d2md lx4d2mw 79.00 250 lx4d2ud ? 79.00 440 lx4d2rd ? 79.00 600 lx4d2xd ? 79.00 specifications average consumption 9 w 11 w operating range at ?55 o c / 131 o f 80?110% of nominal voltage 70?125% of nominal voltage table 18.63: for old d2 lp1d25, d32 ac rated nominal voltage v catalog number catalog number wide range $ price 12 lx4d4jd lx4d4jw 110.00 21 b lx4d4zd ? 110.00 24 lx4d4bd lx4d4bw 110.00 36 lx4d4cd lx4d4cw 110.00 48 lx4d4ed lx4d4ew 110.00 60 lx4d4nd ? 110.00 72 lx4d4sd lx4d4sw 110.00 110 lx4d4fd lx4d4fw 110.00 125 lx4d4gd ? 110.00 220 lx4d4md lx4d4mw 110.00 250 lx4d4ud ? 110.00 440 lx4d4rd ? 110.00 600 lx4d4xd ? 110.00 specifications average consumption 11 w 13 w operating range at < 55 o c / 131 o f 80?110% of nominal voltage 70?125% of nominal voltage a for old style contactors where the catalog number includes the auxiliary contact arrangement (ex. lp1d2510). the new style tesys dc controlled contactors (ex. lc1d25bd) do not have replaceable coils. b for use in 24 volt applications with serial timer modules. refer to page 18-10. c no replacement dc coils for tesys d contactors. specifications average consumption operating range lc1d09-d32, lc1dt20 - lc1dt40 inrush 5.4 w 70 - 125% @ 60 o c sealed 5.4 w lcid tt a inrush 19 w 75 - 125% @ 60 o c sealed 7.4 w low consumption lc1d09-d32, lc1dt20 - lc1dt40 inrush 2.4 w 70 - 125% @ 60 o c sealed 2.4 w table 18.64: for old d2 lp1d40, d50, d65 ac rated nominal voltage v catalog number catalog number wide range $ price 12 lx4d6jd lx4d6jw 124.00 24 lx4d6bd lx4d6bw 36 lx4d6cd lx4d6cw 48 lx4d6ed lx4d6ew 60 lx4d6nd ? 72 lx4d6sd lx4d6sw 124.00 110 lx4d6fd lx4d6fw 125 lx4d6gd ? 220 lx4d6md lx4d6mw 250 lx4d6ud ? 124.00 440 lx4d6rd ? 600 lx4d6xd ? specifications average consumption 22 w 23 w operating range at < 55 o c /131 o f 80?110% of nominal voltage 75?120% of nominal voltage table 18.65: for old d2 lp1d80 and lc1d80 a rated nominal voltage v catalog number catalog number wide range d $ price 12 lx4d7jd lx4d7jw 134.00 24 lx4d7bd lx4d7bw 36 lx4d7cd lx4d7cw 48 lx4d7ed lx4d7ew 60 lx4d7nd ? 72 lx4d7sd lx4d7sw 134.00 110 lx4d7fd lx4d7fw 125 lx4d7gd ? 220 lx4d7md lx4d7mw 250 lx4d7ud ? 440 lx4d7rd ? 134.00 600 lx4d7xd ? specifications average consumption 22 w 23 w operating range at < 55 o c / 131 o f 80?110% nominal voltage 70?120% nominal voltage d wide range coils cannot be used with contactors utilizing both front and side mount auxiliaries. table 18.66: for tesys d lc1d115, 150 rated nominal voltage v catalog number $ price 24 lx4d8bd 78.00 48 lx4d8ed 60 lx4d8nd 72 lx4d8sd 110 lx4d8fd 125 lx4d8gd 78.00 220 lx4d8md 250 lx4d8ud 440 lx4d8rd average consumption inrush 365 w, sealed 5 w operating range at < 55 o c / 131 o f 70%?120% of nominal voltage i12 discount schedule l i m i t e d s t o c k w i l l b e r e p l a c e d w i t h t e s y s l i m i t e d s t o c k w i l l b e r e p l a c e d w i t h t e s y s
www.schneider-electric.us 18 iec contactors and starters 18-20 ? 2009 schneider electric all rights reserved contactors repair parts tesys ? f dc coils refer to catalog 8502ct9901 tesys f dc coils lx4 coils are the standard coils when a voltage code is added to the part number. the lx9 coils may be ordered separately for special applications. lx9 coils do not include a built-in normally open holding circuit contact; a separate auxiliary contact block with a n.o. c ontact should be added to the contactor. both the lx4 and lx9 coils can be used on previous f-line devices. tesys f contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-5, 18-7 tesys f overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 tesys f replacement coils and parts . . . . . . . . . .pages 18-18, 18-18, 18-20 dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-42 to 18-47 table 18.67: lx4 coils for lc1f115, f150, f185, f265, f400, f500, f630, f780, f800 device type catalog number ? catalog number suffix 24 v 36v 48 v 60 v 72 v 110 v 125 v 220 v 250 v 440 v $ price f115, f150 lx4ff ? 024 035 048 060 070 110 125 220 250 440 78.00 f185, f225 lx4fg ? 024 035 048 060 070 110 125 220 250 440 108.00 f265, f330 lx4fh ? 024 035 048 060 070 110 125 220 250 440 138.00 f400 lx4fj ? ? ? 048 060 070 110 125 220 250 440 287.00 lx9fj ? c ? ? 918 ? ? 926 927 932 ? 938 287.00 f500 lx4fk ? ? ? 048 060 070 110 125 220 250 440 360.00 lx9fk ? c ? ? 918 ? ? 926 927 932 ? 938 360.00 f630 lx4fl ? ? ? 048 060 070 110 125 220 250 440 398.00 lx9fk ? c ? ? 918 ? ? 926 927 932 ? 938 398.00 f780 lx4fx ? a ? ? ? ? ? 110 125 220 250 440 795.00 f800 lx4f8 ? b ? ? ? ? ? fw fw mw ? qw 725.00 a lc1f780 contactors operate on 2 coils as a set. the lx4fx part number includes both coils. b also requires rectifier dr5te4u, $72.00 list price. c coil circuit requires a separately mounted resistor. order from table 18.68 below. table 18.68: coil resistor catalog number qty. required $ price coil resistor catalog number qty. required $ price coil resistor catalog number qty. required $ price lx9fj918 dr2sc0047 1 13.70 lx9fk918 dr2sc0039 1 13.70 lx9fl918 dr2sc0047 2 13.70 lx9fj926 dr2sc0030 1 13.80 lx9fk926 dr2sc0220 1 13.70 lx9fl925 dr2sc0270 2 13.70 lx9fj927 dr2sc0390 1 13.70 lx9fk927 dr2sc0330 1 13.70 lx9fl926 dr2sc0330 2 13.70 lx9fj932 dr2sc1200 1 13.70 lx9fk932 dr2sc1000 1 13.70 lx9fl931 dr2sc1000 2 13.70 lx9fj938 dr2sc4700 1 13.70 lx9fk938 dr2sc3300 1 13.70 lx9fl937 dr2sc3900 2 13.70 i12 discount schedule
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-21 enclosed starters tesys ? d in metal enclosures refer to catalog 8502ct9901 dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-48 tesys d enclosed full voltage starters are available in type 1 and type 12/3r enclosures through 50 hp at 460 v. the enclosed d-line accepts standard d-line accessories and all in sta-kits? control units and control power transformer kits. standard capacity control power trans formers with built-in fuse block can be installed in the standard enclosure. for extra capacity, please refer to your local distribut or or nearest square d/sch neider electric sales office. table 18.69: enclosed full voltage non-reversing starters max. horsepower ratings (ac3) auxiliary contacts current rating of contactor catalog number $ price catalog number $ price 1 phase 3 phase 115 230 200 v 230 v 460 v 575v n.o. n.c. type 1 type 12/3r 0.333 1 2 2 5 7.5 1 1 9 le1d093a62????? 109. le1d093a72????? 175. 0.5 2 3 3 7.5 10 1 1 12 le1d123a62????? 137. le1d123a72????? 202. 1 3 5 5 10 15 1 1 18 le1d183a62????? 153. le1d183a72????? 219. 2 3 5 7.5 15 20 1 1 25 le1d253a62????? 170. le1d253a72????? 235. 2 5 7.5 10 20 25 1 1 32 le1d323a62????? 191. le1d323a72????? 245. 3 5 10 10 30 30 1 1 40 le1d403a62????? 273. le1d403a72????? 393. 3 7.5 12 15 40 40 1 1 50 le1d503a62????? 300. le1d503a72????? 420. 5 10 20 20 40 50 1 1 65 le1d653a62????? 393. le1d653a72????? 514. 7.5 15 30 30 60 60 1 1 80 le1d803a62????? 473. le1d803a72????? 610. table 18.70: enclosed full voltage reversing starters max. horsepower ratings (ac3) 3 phase auxiliary contacts on each contactor current rating of contactor catalog number $ price catalog number $ price 200v 230 v 460 v 575 v n.o. n.c. type 1 type 12/3r 2 2 5 7.5 1 1 9 le2d093a62????? 305. le2d093a72????? 382. 3 3 7.5 10 1 1 12 le2d123a62????? 355. le2d123a72????? 453. 5 5 10 15 1 1 18 le2d183a62????? 385. le2d183a72????? 483. 5 7.5 15 20 1 1 25 le2d253a62????? 415. le2d253a72????? 513. 7.5 10 20 25 1 1 32 le2d323a62????? 464. le2d323a72????? 573. 10 10 30 30 1 1 40 le2d403a62????? 655. le2d403a72????? 819. 12 15 40 40 1 1 50 le2d503a62????? 710. le2d503a72????? 874. 20 20 40 50 1 1 65 le2d653a62????? 900. le2d653a72????? 1030. 30 30 60 60 1 1 80 le2d803a62????? 1248. le2d803a72????? 1412. table 18.71: catalog number nomenclature f control power transformer add price from page 18-23. select letter for primary voltage of cpt: voltage no transformer used 208 240 480 600 code o a lmtx a letter o, not zero. note: if control transformer is used, the only options available are 24 or 120 volts as the secondary of the transformer. also, dc voltages are not available when control power transformer is used. g contactor/starter coil voltage select coil voltage from table: volt ag e 24 120 208 240 480 600 ac bglutx dc b ????? h coil frequency select: 7 = dual frequency coils (50/60 hz.) 6 = 60 hz. d=dc note: for 9 to 65 a contactors, only dual frequency coils are available; 80 a contactors, the 24 v to 240 v coils are dual frequency only (50/60 hz.). the 480 v to 600 v coils are 60 hz. only. see catalog for other restrictions. j overload relay type select: 0 = no overload relay 1 = class 10 trip 2 = class 20 trip le1d09 3 a62 o g 7 1 07 overlo a d rel a y r a nge i overlo a d rel a y type j coil fre qu ency h cont a ctor/ s t a rter coil volt a ge g control power tr a n s former f wiring method b as e c a t a log n u m b er c a t a log n u m b er ex a mple: i overload relay range select code from the below: code range for use on contactors $ price adder 01 0.1?0.16 d09?d32 b 60. 02 0.16?0.25 d09?d32 b 60. 03 0.25?0.40 d09?d32 b 60. 04 0.40?0.63 d09?d32 b 60. 05 0.63?1.0 d09?d32 b 60. 06 1.0?1.6 d09?d32 b 60. 07 1.6?2.5 d09?d32 b 60. 08 2.5?4 d09?d32 60. 10 4?6 d09?d32 60. 12 5.5?8 d09?d32 60. 13 9?13 d40, d50, d65 107. 14 7?10 d09?d32 62. 16 9?13 d12?d32 62. 18 12?18 d40, d50, d65 107. 21 12?18 d18?d32 62. 22 16?24 d25?d32 b 62. 17?25 d25?d32 c 62. 17?25 d80 107. 25 17?25 d40, d50, d65 107. 30 23-28 d25?d32 c 73. 32 23?32 d25?d32 73. 32 23?32 d40, d50, d65 107. 40 30?40 d40, d50, d65 107. 50 37?50 d40, d50, d65 107. 53 30?38 d80 107. 55 30?40 d80 107. 57 37?50 d80 107. 59 48?65 d80 107. 61 55?70 d65?d80 107. 63 63?80 d65?d80 107. 65 48?65 d40, d50, d65 107. b available for class 10 only. c available for class 20 only. note: if no overload relay is required, leave this portion of the catalog blank. add appropriate price adder to the base price of the starter. i11 discount schedule
www.schneider-electric.us 18 iec contactors and starters 18-22 ? 2009 schneider electric all rights reserved enclosed combination starters tesys ? d fusible disconnect swit ch or circuit breaker refer to catalog 8502ct9901 iec combination starters combine the requirements of mo tor overload and short circuit protection in one convenient compact package. all devices provide type 2 coordination through 30 hp at 460 v. devices are available in type 1 and type 12/3r enclosures. the iec combination starter li ne accepts standard tesys d accessories and all insta-kits ? pilot devices and control power transformer kits. standard capacity control pow er transformers with built-in fuse block can be installed in the standard enclosure. for extra capacit y, please refer to your local distributor or nearest square d/schneider electric sales office. note: use tables and notes from page 18-21 to complete the catalog numbers. dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-48 table 18.72: enclosed full voltage non-reversing fusible combination starters max. horsepower ratings (ac3) fuse clip rating auxiliary contacts current rating of contactor catalog number $ price catalog number $ price 3 phase 200 v 230 v 460 v 575 v amperes ul class n.o. n.c. type 1 type 12/3r 2 2 5 7.5 30 a cc 1 1 9 le1d096b62????? 426. le1d096b72????? 551. 3 3 7.5 10 30 a cc 1 1 12 le1d126b62????? 468. le1d126b72????? 592. 5 5 10 15 30 a j 1 1 18 le1d186b62????? 484. le1d186b72????? 607. 5 7.5 15 20 30 a j 1 1 25 le1d256b62????? 500. le1d256b72????? 623. 7.5 10 20 25 60 a j 1 1 32 le1d326c62????? 653. le1d326c72????? 829. 10 10 30 30 60 a j 1 1 40 le1d406c62????? 708. le1d406c72????? 877. table 18.73: enclosed full voltage reversing fusible combination starters max. horsepower ratings (ac3) fuse clip rating aux. contacts each contactor current rating of contactor catalog number $ price catalog number $ price 3 phase 200 v 230 v 460 v 575 v amperes ul class n.o. n.c. type 1 type 12/3r 2 2 5 7.5 30 a cc 1 1 9 le2d096b62????? 712. le2d096b72????? 837. 3 3 7.5 10 30 a cc 1 1 12 le2d126b62????? 778. le2d126b72????? 915. 5 5 10 15 30 a j 1 1 18 le2d186b62????? 808. le2d186b72????? 950. 5 7.5 15 20 30 a j 1 1 25 le2d256b62????? 833. le2d256b72????? 980. 7.5 10 20 25 60 a j 1 1 32 le2d326c62????? 1089. le2d326c72????? 1281. 10 10 30 30 60 a j 1 1 40 le2d406c62????? 1179. le2d406c72????? 1371. table 18.74: enclosed full voltage non-reversing circuit breaker combination starters max. horsepower ratings (ac3) auxiliary contacts circuit breaker maximum current rating current rating of contactor catalog number $ price catalog number $ price 3 phase 200 v 230 v 460 v 575 v n.o. n.c. type 1 type 12/3r 2 2 5 7.5 1 1 15 a 9 le1d097d62????? 569. le1d097d72????? 730. 3 3 7.5 10 1 1 15 a 12 le1d127d62????? 622. le1d127d72????? 789. 5 5 10 15 1 1 30 a 18 le1d187e62????? 647. le1d187e72????? 808. 5 7.5 15 20 1 1 30 a 25 le1d257e62????? 668. le1d257e72????? 834. 7.5 10 20 25 1 1 50 a 32 le1d327f62????? 870. le1d327f72????? 1088. 10 10 30 30 1 1 50 a 40 le1d407f62????? 944. le1d407f72????? 1179. table 18.75: enclosed full voltage reversing circuit breaker combination starters max. horsepower ratings (ac3) auxiliary contacts each contactor circuit breaker maximum current rating current rating of contactor catalog number $ price catalog number $ price 3 phase 200 v 230 v 460 v 575 v n.o. n.c. type 1 type 12/3r 2 2 5 7.5 1 1 15 a 9 le2d097d62????? 836. le2d097d72????? 972. 3 3 7.5 10 1 1 15 a 12 le2d127d62????? 944. le2d127d72????? 1096. 5 5 10 15 1 1 30 a 18 le2d187e62????? 1010. le2d187e72????? 1174. 5 7.5 15 20 1 1 30 a 25 le2d257e62????? 1075. le2d257e72????? 1251. 7.5 10 20 25 1 1 50 a 32 le2d327f62????? 1403. le2d327f72????? 1631. 10 10 30 30 1 1 50 a 40 le2d407f62????? 1522. le2d407f72????? 1770. table 18.76: enclosed full voltage non-reversing non-fused combination starters max. horsepower ratings (ac3) fuse clip rating auxiliary contacts current rating of contactor catalog number $ price catalog number $ price 3 phase 200 v 230 v 460 v 575 v amperes ul class n.o. n.c. type 1 type 12/3r 2 2 5 7.5 30 a cc 1 1 9 le1d096a62????? 416. le1d096a72????? 541. 3 3 7.5 10 30 a cc 1 1 12 le1d126a62????? 458. le1d126a72????? 532. 5 5 10 15 30 a j 1 1 18 le1d186a62????? 474. le1d186a72????? 597. 5 7.5 15 20 30 a j 1 1 25 le1d256a62????? 490. le1d256a72????? 613. 7.5 10 20 25 60 a j 1 1 32 le1d326a62????? 643. le1d326a72????? 819. 10 10 30 30 60 a j 1 1 40 le1d406a62????? 698. le1d406a72????? 867. table 18.77: enclosed full voltage reversing non-fused combination starters max. horsepower ratings (ac3) fuse clip rating aux. contacts each contactor current rating of contactor catalog number $ price catalog number $ price 3 phase 200 v 230 v 460 v 575 v amperes ul class n.o. n.c. type 1 type 12/3r 2 2 5 7.5 30 a cc 1 1 9 le2d096a62????? 702. le2d096a72????? 827. 3 3 7.5 10 30 a cc 1 1 12 le2d126a62????? 768. le2d126a72????? 905. 5 5 10 15 30 a j 1 1 18 le2d186a62????? 798. le2d186a72????? 940. 5 7.5 15 20 30 a j 1 1 25 le2d256a62????? 823. le2d256a72????? 970. 7.5 10 20 25 60 a j 1 1 32 le2d326a62????? 1079. le2d326a72????? 1271. 10 10 30 30 60 a j 1 1 40 le2d406a62????? 1169. le2d406a72????? 1361. i11 discount schedule
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-23 enclosed combination starters enclosure modifications/insta-kits?/overload relay refer to catalog 8502ct9901 factory modifications and insta-kits ? selection add the factory modification code to the end of the catalog number created from page 18-21. with the use of insta-kits ? , only one operator scheme is allowed. only the combinations of operators and pilot lights shown below can be ordered. pilot lights will be at the coil voltage indi cated in the catalog number for the starter. l1 l2 pl m off on 12 3 4a b olr 95 96 x1 x2 pl 61 62 x1 x2 l1 l2 m hand auto off pl x1 x2 3 4 3 4 95 96 61 62 pl x1 x2 remote b y c us tomer connection l1 l2 s ta rt s top 12 ab 3 4 m 95 96 1 3 14 olr start/stop on-off selector switch hoa selector switch l1 l2 l 3 m 9 8 97 b a 96 95 1 3 14 t1 t2 t 3 d-line ac magnetic starter 2-3 poll l1 l2 l 3 21 22 + + b a b a f r t1 t2 t 3 21 22 + + 97 9 8 96 95 "c" d-line ac magnetic reversing starter 3-pole table 18.78: description factory modification code a $ price insta-kits (for field installation) $ price control units only for-rev-stop push button a06l 131. la9ca06lt 71.00 start/stop push button a06g 65. la9ca06gt 32.80 i/o (start/stop) push button n/a ? n/a ? i/o push button (double touch) a06i 83. la9ca06io 41.50 emergency stop n/a ? n/a ? hand-off-auto selector switch a06e 65. la9ca06et 32.80 on/off selector switch a06d 65. la9ca06dt 41.50 start/mushroom head stop push button a06x 65. la9ca06xt 63.00 pilot lights only led pilot light, 24, 120 or 240 v a16s 134. la9ca16st d 66.00 green-red pilot light, direct supply, 24 or 120 v b a06s 112. la9ca06st d 62.00 green-red transformer pilot light, 120, 208/240, 480 or 600 v b a06f 207. la9ca06ft d 113.00 available combination of control units and pilot lights hand-off-auto selector switch w/24, 120 or 240 v led pilot light a16u 213. la9ca16ut d 177.00 start/stop push button w/ 24, 120 or 240 v led pilot light a16v 213. la9ca16vt d 177.00 on/off selector w/ 24, 120 or 240 v led pilot light a16w 213. la9ca16wt d 177.00 start/stop push button w/ green-red transformer pilot light a06n 177. la9ca06nt d 95.00 start/stop push button w/green-red pilot light a06v 177. la9ca06vt 95.00 hand-off-auto selector sw itch w/green-red pilot light a06u 273. la9ca06ut 97.00 hand-off-auto selector switch w/green-red transformer pilot light a06j 273. la9ca06jt d 147.00 on/off selector w/green-red pilot light a06w 177. la9ca06wt 95.00 on/off selector w/green-red transformer pilot light a06h 273. la9ca06ht d 147.00 control power transformer standard va, 2 fuses in primary, 1 fuse in secondary a206p 260. c ? 50 va extra, 2 fuses in primary, 1 fuse in secondary a207p 456. c ? 100 va extra, 2 fuses in primary, 1 fuse in secondary a208p 634. c ? a add these forms to the catalog number selected on page 18-21. the numbers as shown are for use in nema 1 enclosures. for uses in nema 12/3r change the 6 to a 7 (ex a06u becomes a07u). price remains the same. the change does not apply to control power transformer forms. b pilot lights are wired such that the light is on when the contactor is energized. for non-led type pilot lights, a green lens is installed on the unit when shipped. a red lens is included for use as applicable. c select insta-kits ? from table below. table 18.79: total va insta-kits? catalog number $ price 50 la9tfd32 d 140.00 100 la9tfd80 d 246.00 150 la9tfd15 d 343.00 d complete the part number for the insta-kits ? by selecting the voltage code from the appropriate tables below. table 18.80: voltage codes for pilot lights voltage (vac) 24 120 208/240 480 600 code bgmtx table 18.81: voltage codes for control power transformers primary voltage 120 208 240 480 600 208 240 480 600 secondary voltage 24 120 code edcbalmtx i11 discount schedule
www.schneider-electric.us 18 iec contactors and starters 18-24 ? 2009 schneider electric all rights reserved contactors tesys ? k 3-pole non-reversing contactors refer to catalog 8502ct9901 3-pole non-reversing mini-contactors , accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-27 dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-49 lc1k0610g7 table 18.82: ac operating coils maximum horsepower ratings maximum current type of connection auxiliary contacts catalog number $ price 1 ? 3 ? inductive ac3 amperes resistive ac1 amperes 115 v hp 230 v hp 200 v hp 230 v hp 460 v hp 575 v hp n.o. n.c. 0.5 1.5 1.5 1.5 3 3 6 15 screw-clamp 1 ? ? lc1k0610 a b 57. 1 lc1k0601 ab 57. 0.51.52355 9 20 screw-clamp 1 ? lc1k0910 ab 75. ? 1 lc1k0901 ab 75. 0.5 1.5 3 3 7.5 10 12 20 screw-clamp 1 ? lc1k1210 ab 86. ? 1 lc1k1201 ab 86. table 18.83: coil voltage codes for ac contactors up to and including 240 v coil with integral suppression device available. add 2 to the code required. example j72. price adder $10.00. volts ac 50/60 hz 12 24 42 48 110 120 127 200/ 208 220/ 230 230 230/ 240 277 380/ 400 400/ 415 440 480 660/ 690 code j7 b7 d7 e7 f7 g7 fc7 l7 m7 p7 u7 ue7 q7 n7 r7 t7 y7 table 18.84: dc operating coils 0.5 1.5 1.5 1.5 3 3 6 15 screw-clamp 1 ? lp1k0610 ab 75. ? 1 lp1k0601 ab 75. 0.51.52355 9 20 screw-clamp 1 ? lp1k0910 ab 92. ? 1 lp1k0901 ab 92. 0.5 1.5 3 3 7.5 10 12 20 screw-clamp 1 ? lp1k1210 ab 106. ? 1 lp1k1201 ab 106. table 18.85: coil voltage codes for dc contactors coil with integral suppression device available. add 3 to the code required. example jd3. price adder $10.00. volts dc 12 20 24 36 48 60 72 100 110 125 200 220 230 240 250 code jd zd bd cd ed nd sd kd fd gd ld md mpd mud ud table 18.86: dc?low consumption operating coils (devices have built-in transient suppression) 0.5 1.5 1.5 1.5 3 3 6 15 screw-clamp 1 ? lp4k0610 ab 92. ? 1 lp4k0601 ab 92. 0.51.52355 9 20 screw-clamp 1 ? lp4k0910 ab 110. ? 1 lp4k0901 ab 110. 0.5 1.5 3 3 7.5 10 12 20 screw-clamp 1 ? lp4k1210 ab 126. ? 1 lp4k1201 ab 126. table 18.87: coil voltage codes for dc contactors?low consumption volts dc 12 24 48 72 code jw3 bw3 ew3 sw3 a for tesys k contactors with spring terminal clamps, add a ?3? before the coil voltage code (ex. lc1k06103g7). for tesys k contactors with solder pin terminals, add a ?5? before the coil voltage code (ex. lc1k09105b7). for tesys k contactors with slip-on terminals, add a ?7? before the coil voltage code (ex. lc1k12107m7). b complete the catalog number with the appropriate coil voltage code. for example: lc1k0610g7. table 18.88: overload relays for 3-pole contactors with screw-clamp terminals class 10, relay setting range?a catalog number $ price 0.1 to 0.16 lr2k0301 59. lr2k overload relays: ? ac or dc protection ? ambient compensated bimetallic ? class 10 ? single phase sensitivity ? manual or auto reset ? full load current dial 0.16 to 0.23 lr2k0302 59. 0.23 to 0.36 lr2k0303 59. 0.36 to 0.54 lr2k0304 59. 0.54 to 0.8 lr2k0305 59. 0.8 to 1.2 lr2k0306 59. 1.2 to 1.8 lr2k0307 59. 1.8 to 2.6 lr2k0308 59. 2.6 to 3.7 lr2k0310 59. 3.8 to 5.5 lr2k0312 59. 5.5 to 8 lr2k0314 59. 8 to 11.5 lr2k0316 59. 10 to 14 lr2k0321 59. lp1k0610 lp4k06105 lr2k0316 e164862 ccn nldx (screw terminals) lr43364 class 3211 04 e164862 ccn nldx2 (slip-on & solder-pin terminals) i11 discount schedule
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-25 contactors tesys ? k 3-pole reve rsing contactors refer to catalog 8502ct9901 3-pole reversing mini-contactors overload relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-24 accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-27 dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-49 lc2k09107 lp2k0910 lp2k09105 table 18.89: ac operating coils maximum horsepower ratings maximum current type of connection auxiliary contacts catalog number $ price 1? 3? inductive ac3 a resistive ac1 a 115v hp 230v hp 200v hp 230v hp 460v hp 575v hp n.o. n.c. 0.5 1.5 1.5 1.5 3 3 6 15 screw-clamp 1 ? lc2k0610 ab 130. ? 1 lc2k0601 ab 130. 0.51.52355920 screw-clamp 1 ? lc2k0910 ab 167. ? 1 lc2k0901 ab 167. 0.5 1.5 3 3 7.5 10 12 20 screw-clamp 1 ? lc2k1210 ab 191. ? 1 lc2k1201 ab 191. table 18.90: coil voltage codes for ac contactors up to and including 240 v coil with integral suppression device available. add 2 to the code required. example j72. price adder $20.00. vo lt s ac 50/60 hz 12 24 42 48 110 120 127 200/2 08 220/ 230 230 230/ 240 277 380/ 400 400/ 415 440 480 660/ 690 code j7 b7 d7 e7 f7 g7 fc7 l7 m7 p7 u7 ue7 q7 n7 r7 t7 y7 table 18.91: dc operating coils 0.5 1.5 1.5 1.5 3 3 6 15 screw-clamp 1 ? lp2k0610 ab 167. ? 1 lp2k0601 ab 167. 0.51.52355920 screw-clamp 1 ? lp2k0910 ab 202. ? 1 lp2k0901 ab 202. 0.5 1.5 3 3 7.5 10 12 20 screw-clamp 1 ? lp2k1210 ab 232. ? 1 lp2k1201 ab 232. table 18.92: coil voltage codes for dc contactors coil with integral suppression device available. add 3 to the code required. example jd3. price adder $20.00. volts dc 12 20 24 36 48 60 72 100 110 125 200 220 230 240 250 code jd zd bd cd ed nd sd kd fd gd ld md mpd mud ud table 18.93: dc?low consumption operating coils (devices have built-in transient suppression) 0.5 1.5 1.5 1.5 3 3 6 15 screw-clamp 1 ? lp5k0610 ab 202. ? 1 lp5k0601 ab 202. 0.51.52355920 screw-clamp 1 ? lp5k0910 ab 238. ? 1 lp5k0901 ab 238. 0.51.5 3 3 7.5101220 screw-clamp 1 ? lp5k1210 ab 274. ? 1 lp5k1201 ab 274. table 18.94: coil voltage codes for dc contactors?low consumption volts dc 12 24 48 72 code jw3 bw3 ew3 sw3 a for tesys k contactors with spring terminal clamps, add a ?3? before the coil voltage code (ex. lp2k09103bd). for tesys k contactors with solder pin terminals, add a ?5? before the coil voltage code (ex. lp5k09105bw3). for tesys k contactors with slip-on terminals, add a ?7? before the coil voltage code (ex. lc2k06107b7). b complete the catalog number with the appropriate coil voltage code. for example: lc1k0610g7. i11 discount schedule
www.schneider-electric.us 18 iec contactors and starters 18-26 ? 2009 schneider electric all rights reserved contactors tesys ? k 4-pole contactors refer to catalog 8502ct9901 overload relays. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-24 accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-27 dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-49 lc2k090045 table 18.95: ac operating coils maximum horsepower ratings maximum current type of connection power poles catalog number $ price 1 ph 3 ph inductive ac3 a resistive ac1 a 115 v hp 230 v hp 200 v hp 230 v hp 460 v hp 575 v hp n.o. n.c. 4-pole mini contactor 0.51.52355915 screw-clamp 4 ? lc1k09004 ab 75. 2 2 lc1k09008 ab 81. 0.5 1.5 3 3 7.5 10 12 20 screw-clamp 4 ? lc1k12004 ab 86. 4-pole mechanically interlocked contactors 0.51.52355920 screw-clamp 4?lc2k09004 ab 167. 0.5 1.5 3 3 7.5 10 12 20 screw-clamp 4 ? lc2k12004 ab 191. table 18.96: coil voltage codes for ac contactors up to and including 240 v coil with integral suppression device available. add 2 to the code required. example j72. price adder $10.00 ($20.00 for mechanically interlocked contactors) volts ac 50/60 hz 12 24 42 48 110 120 127 200/208 220/230 230 230/ 240 277 380/400 400/415 440 480 660/690 code j7 b7 d7 e7 f7 g7 fc7 l7 m7 p7 u7 ue7 q7 n7 r7 t7 y7 table 18.97: dc operating coils 4-pole mini contactor 0.5 1.5 2 3 5 5 9 15 screw-clamp 4 ? lp1k09004 ab 92. 2 2 lp1k09008 ab 98. 0.5 1.5 3 3 7.5 10 12 20 screw-clamp 4 ? lp1k12004 ab 106. 4-pole mechanically interlocked contactors 0.5 1.5 2 3 5 5 9 20 screw-clamp 4 ? lp2k09004 ab 202. 0.5 1.5 3 3 7.5 10 12 20 screw-clamp 4 ? lp2k12004 ab 232. table 18.98: coil voltage codes for dc contactors coil with integral suppression device available. add 3 to the code required. example jd3. price adder $10.00 ($20.00 for mechanically interlocked contactors) volts dc 12 20 24 36 48 60 72 100 110 125 200 220 230 240 250 code jd zd bd cd ed nd sd kd fd gd ld md mpd mud ud table 18.99: dc?low consumption operating coils (devices have built-in transient suppression) 4-pole mini contactor 0.5 1.5 2 3 5 5 9 15 screw-clamp 4 ? lp4k09004 ab 110. 2 2 lp4k09008 ab 116. 0.5 1.5 3 3 7.5 10 12 20 screw-clamp 4 ? lp4k12004 ab 126. 4-pole mechanically interlocked contactors 0.5 1.5 2 3 5 5 9 20 screw-clamp 4 ? lp5k09004 ab 238. 0.5 1.5 3 3 7.5 10 12 20 screw-clamp 4 ? lp5k12004 ab 274. table 18.100: coil voltages for dc contactors?low consumption volts dc 12 24 48 72 code jw3 bw3 ew3 sw3 a for tesys k contactors with spring terminal clamps, add a ?3? before the coil voltage code (ex. lc1k09103l7). for tesys k contactors with solder pin terminals, add a ?5? before the coil voltage code (ex. lp4k06015jw3). for tesys k contactors with slip-on terminals, add a ?7? before the coil voltage code (ex. lp2k090047bd). b complete the catalog number with the appropriate coil voltage code. for example: lc1k0610g7. i11 discount schedule
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-27 contactors and accessories tesys ? k contactors and accessories refer to catalog 8502ct9901 la1kn11 la1kn22 e164862 ccn nldx lr43364 class 3211 04 table 18.101: instantaneous auxiliary contact blocks clip-on front mounting, 1 block per c ontactor and 2 blocks per pair of mechanically interlocked contactors. type of connection auxiliary contacts catalog number $ price n.o. n.c. screw clamp 2? la1kn20 14.20 ?2 la1kn02 14.20 11 la1kn11 14.20 4? la1kn40 a 27.30 31 la1kn31 a 27.30 22 la1kn22 a 27.30 13 la1kn13 a 27.30 ?4 la1kn04 a 27.30 slip-on 1 x .250" or 2 x .110" 2? la1kn207 14.20 ?2 la1kn027 14.20 11 la1kn117 14.20 4? la1kn407 a 27.30 31 la1kn317 a 27.30 22 la1kn227 a 27.30 13 la1kn137 a 27.30 ?4 la1kn047 a 27.30 a block of 4 contacts cannot be used with lp4k or lp5k contactors. la2kt2u table 18.102: electronic time delay auxiliary contact blocks clip-on front mounting, 1 block per c ontactor and 2 blocks per pair of mechanically interlocked contactors. voltage (v) type timing range (s) contacts catalog number $ price 24 to 48 vac or vdc on-delay 1 to 30 spdt la2kt2e 32.80 110 to 240 vac on-delay 1 to 30 spdt la2kt2u 32.80 note: relay outputs, with single pole double throw, 240 vac/dc, 2 a max. note: maximum switching capacity 250 va / 150 w note: operating temperature: -10 to + 60c (14 to 140f) note: reset time: 1.5 s during ti me delay, 0.5 after time delay table 18.103: suppressor module with incorporated led indicator clip-on front mounting voltage range type sold in lots of catalog number $ price each 12 to 24 vac and dc varistor 5 la4ke1b b 9.80 32 to 48 vac and dc varistor 5 la4ke1e b 9.80 50 to 129 vac and dc varistor 5 la4ke1fc b 9.80 130 to 250 vac and dc varistor 5 la4ke1ug b 9.80 12 to 24 vdc diode + zener 5 la4kc1b c 9.80 32 to 48 vdc diode + zener 5 la4kc1e c 9.80 220 to 250 vac rc 5 la4ka1u d 9.80 b protection by limitation of the transient voltage to 2 uc maximum. maximum reduction of the transient voltage peaks. slight tim e delay on drop-out (1.1 to 1.5 times normal). c no overvoltage or oscillation frequency. polarized component. slight time delay on drop-out (1.1 to 1.5 times normal). d protection by limitation of the transient voltage to 3 uc maximum and limitation of the oscillation frequency. slight time dela y on drop-out (1.2 times normal). table 18.104: paralleling links description sold in lots of catalog number $ price each for 2 poles with screw-clamp terminals 4 la9e01 2.20 for 4 poles with screw-clamp terminals 2 la9e02 3.50 table 18.105: power connectors description sold in lots of catalog number $ price each set of 6 power connections for reversing contactors with screw-clamp terminals 100 la9k0969 6.20 set of 4 power connections for changeover contactors with screw-clamp terminals 100 la9k0970 6.20 table 18.106: marking strips description sold in lots of catalog number $ price each clips onto front of the contactor 100 la9d90 .06 table 18.107: accessories for overload relays description type of connect ion catalog number $ price terminal block for separate clip-on mounting of the overload relay onto 35 mm omega rail (am1dp200) screw-clamp la7k0064 11.90 i11 discount schedule
www.schneider-electric.us 18 iec contactors and starters 18-28 ? 2009 schneider electric all rights reserved the tesys u motor starter is integrated, simple to choose and to install, consisting of a control unit snapped in a power base. tesys u can be configured to fit sp ecific applications as well. optional ac cessories: reverser, current limiter, predictive maintenance options and communication options. to get details information about tesys u, visit our web at www.us.schneider-electric.com/tesysu. selecting tesys u motor starters in three steps accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-29 to 18-31 dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-50 table 18.108: step 1. select power base (only two different bases up to 32 amps.) control connection max. current (amps) three phase (hp max.) single phase (hp max.) self-protected power base 200/208 v 220/240 v 460 v 575/600 v 120 v 240 v catalog number $ price with screw terminations 12 3 3 7.5 10 1.5 2 lub12 246.00 32 10 10 20 25 2 5 lub32 345.00 table 18.109: step 2. select control unit g setting range (amps) standard 3-phase class 10 trip e $ price advanced 3-phase class 10 trip e $ price advanced single-phase class 10 trip e $ price advanced 3-phase class 20 trip e $ price 0.15?0.6 lucax6 ?? 120.00 lucbx6 ?? 150.00 luccx6 ?? 150.00 lucdx6 ?? 150.00 0.3?1.4 luca1x ?? 120.00 lucb1x ?? 150.00 lucc1x ?? 150.00 lucd1x ?? 150.00 1.25?5.0 luca05 ?? 120.00 lucb05 ?? 150.00 lucc05 ?? 150.00 lucd05 ?? 150.00 3?12 luca12 ?? 120.00 lucb12 ?? 150.00 lucc12 ?? 150.00 lucd12 ?? 150.00 4.5?18 f luca18 ?? 120.00 lucb18 ?? 150.00 lucc18 ?? 150.00 lucd18 ?? 150.00 8?32 f luca32 ?? 120.00 lucb32 ?? 150.00 lucc32 ?? 150.00 lucd32 ?? 150.00 e complete catalog number by adding appropriate code from voltage code table below. for example: lucax6fu. f control units for 4.5?18 and 8?32 can be used only with 32 amp rated power bases (lub32 / lu2b32). g the control unit contains solid state overload relay and control power source for tesys u. for more details on the different co ntrol units, their functions, and placement on the power base, see 18-29 table 18.110: voltage codes volts 24 48?72 110?240 dc bl h ?? ac b ? ? dc or ac ? es i fu h dc voltage with range of 0.90 to 1.10 of nominal. i 48?72 vdc; 48 vac table 18.111: step 3. select auxiliary contacts (optional) auxiliary contact blocks terminals contact indicates contact normal status contact state for each mode a catalog number $ price off ready run short circuit trip overload trip (manual reset) overload trip (remote/ auto reset) b screw ready condition n.o. o i i o o i lua1c11 34.5 fault condition n.c. i i i o o i screw ready condition n.o. o i i o o i lua1c20 fault condition n.o. o o o i i o auxiliary contac t function modules screw pole state 2 n.o. o o i o o lufn20 34.5 screw pole state 1 n.o. and 1 n.c. o i o i i o o i o i lufn11 screw pole state 2 n.c. 1 i o i i lufn02 a i?indicates closed contact; o?indicates open contact b requires multifunction or advanced control unit plus fault differentiation module lufda10. accessory quick descri ption for details & selection, see pages: current limiter increases the breaking capacity to 130ka @ 460 v 18-30 reverser stacked or side mounted 18-30 line phase barrier required for use as a self-protected combination starter (ul508e) 18-30 multifunction control unit has functions for monitoring and predictive maintenance 18-30 function modules fault differentiation, thermal overload, motor load indication 18-30 communication modules integrates into existing networks, major portocols are available 18-31 soft starter + tesys u use altistart u01soft starter with tesys u 18-32 powerbus use tesys u with a prewired system 18-31 configuration and connection accessories powersuite software, busbar, external handle 18-31 control unit function modules auxiliary contacts + power base te s y s ? u motor starter = 1 2 3 power base control unit auxiliary contact e164862 ccn nldx lr43364 class 3211 08 motor starters tesys ? u simple motor starter refer to catalog 8502ct0201 i11 discount schedule
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-29 control units tesys ? u simple motor starter refer to catalog 8502ct0201 power base and plug-in accessories find below where to install the accessories to the power base. only one accessory can be installed in each location. table 18.112: control units and functions standard advanced multifunction reference luca lucb lucc lucd lucm protection type class 10 class 20 class 5?30 single phase: lucc class 10 only protection functions short circuit over current thermal overload phase loss phase imbalance ground fault under load, long start, jam control functions manual reset automatic or local/remote reset fault differentiation thermal alarm motor load display fault history alarm threshold adjustment tripping test = built-in the control unit = works with the related function modules (see table 18.119 on page 30) control unit or multifunction control auxiliary function or communication module auxiliary contact block control circuit contact block b line phase barrier e reverser unit mounts under power base j current limiter attaches under power base m multifunction control unit m    power base (front view) b e j side view
www.schneider-electric.us 18 iec contactors and starters 18-30 ? 2009 schneider electric all rights reserved accessories tesys ? u simple motor starter refer to catalog 8502ct0201 table 18.113: line phase barrier (optional) a description catalog number $ price for use as a self protected combination starter, ul508e, incoming line phase barrier must be used. lu9sp0 15.00 a see page 18-29 for placement on the power base. table 18.114: reverser b control connection max. current (amps) three phase (hp max.) self-protected starter base 200/208 v 220/240 v 460 v 575 v catalog number $ price with screw terminations 12 3 3 7.5 10 lu2b12 c 488.00 32 10 10 20 25 lu2b32 c 720.00 b see page 18-29 for placement on the power base. c voltage code required. select control unit options ef setting range (amps) standard 3-phase class 10 trip d $ price advanced 3-phase class 10 trip d $ price advanced single-phase class 10 trip d $ price advanced 3-phase class 20 trip d $ price 0.15?0.6 lucax6 ?? 120.00 lucbx6 ?? 150.00 luccx6 ?? 150.00 lucdx6 ?? 150.00 0.3?1.4 luca1x ?? 120.00 lucb1x ?? 150.00 lucc1x ?? 150.00 lucd1x ?? 150.00 1.25?5.0 luca05 ?? 120.00 lucb05 ?? 150.00 lucc05 ?? 150.00 lucd05 ?? 150.00 3?12 luca12 ?? 120.00 lucb12 ?? 150.00 lucc12 ?? 150.00 lucd12 ?? 150.00 4.5?18 d luca18 ?? 120.00 lucb18 ?? 150.00 lucc18 ?? 150.00 lucd18 ?? 150.00 8?32 d luca32 ?? 120.00 lucb32 ?? 150.00 lucc32 ?? 150.00 lucd32 ?? 150.00 d complete catalog number by adding appropriate code from voltage code table below. for example: lucax6fu. e control units for 4.5?18 and 8?32 can be used only with 32 amp rated power bases (lub32 / lu2b32). f the control unit contains solid state overload relay and control power source for tesys u. for more details on the different control units, their functions, and placement on the power base see page 18-29. table 18.115: voltage codes volts 24 48?72 110?240 dc bl gb ?? ac b ? ? dc or ac ? es j fu g voltage code to use for a power base with a communication module. h dc voltage with range of 0.90 to 1.10 of nominal. i 48?72 vdc; 48 vac table 18.116: current limiter jk accessory application t echnical data mounting catalog number $ price current limiter/isolator additional current limiting aspects for the starter 130 ka at 460 v 60 ka at 575 v direct mounting to lub ? and lu2b ? lualb1 171.00 limiter cartridge replacement cartridge for lualb1 130 ka at 460 v 65 ka at 575 v ? lualf1 78.00 j increases the breaking capacity of the motor starter. k see page 18-29 for placement on the power base. table 18.117: control unit multifunction lm setting range (amps) multifunction programmable $ price 0.15?0.6 lucmx6bl 615.00 0.3?1.4 lucm1xbl 1.25?5.0 lucm05bl 3?12 lucm12bl 4.5?18 lucm18bl 8?32 lucm32bl l offers motor management system capabilities. fo r more details see the lucm on page 18-31. m see page 18-29 for placement on the power base. table 18.118: function modules no module description for use with: operation requirements catalog number $ price fault differentiation with manual reset (thermal overload) provides indication between an overload trip and a short circuit trip. advanced control units only 24?250 vac or vdc (power from control unit) lufdh20 156.00 fault differentiation with auto reset lufda10 156.00 thermal overload pre-alarm signals when the motor current reaches 1.05 of the full load setting on the control unit. advanced control units only 24?250 vac or vdc (power from control unit) lufw10 156.00 motor load indication provides a signal proportional to the average currents in the three phases divided by the full load current setting of the control unit. the output corresponds to a load status of 0?2 times the full load setting of the control unit. advanced or multi-function control units 4?20 ma (requires separate 24 vdc power supply) lufv2 188.00 parallel wiring provides a convenient way to reduce control wiring and allow for connecting starters to a communications network by providing 24 vdc for the starters. advanced or multi-function control units(24 vdc only) and lu9bn11c or lu9mrc pre- wired connector lu9g02 splitter box and plc network lufc00 57.00 n offers customization for specific application requirements. o see page 18-29 for placement on the power base. line phase barrier reverser unit assembled under the power base current limiter and its cartridge control unit multifunction motor load indicator alarm differentiation parallel wiring i11 discount schedule
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-31 accessories tesys ? u simple motor starter refer to catalog 8502ct0201 configuration and co nnection accessories \ powerbus additional accessories and compon ents are available, including: ? mounting accessories ? gateways ? cabling accessories ? magelis ? remote display unit for the complete line of tesys u-line motor starter accessories and all technica l details (specifications, wiring diagrams, etc.) pertaining to t he product line, refer to catalog 8502ct0201. table 18.119: communication modules de module description for use with: operation requirements catalog number $ price as-interface communication allows the tesys u starter to be connected directly to the network using as-interface protocols. advanced or multi-function control units (24 vdc only) and lu9bn11c or lu9mrc pre-wired connector requires separate 24 vdc power supply and as-interface network asilufc5 188.00 as-interface v2 communication allows the tesys u starter to be connected directly to the network using as-interface v2 protocols. advanced or multi-function control units (24 vdc only) and lu9bn11c or lu9mrc pre-wired connector requires separate 24 vdc power supply and as-interface v2 network asilufc51 188.00 modbus ? communication protocol allows the tesys u starter to be connected directly to the network using modbus protocols. advanced or multi-function control units (24 vdc only) and lu9bn11c or lu9mrc pre-wired connector requires separate 24 vdc power supply lulc033 218.00 advantys? stb communication allows the tesys u starter to be connected to the network using the advantsys stb protocol advanced or multi-function control units (24 vdc only) and lu9bn11l or lu9mrl pre-wired connector requires separate 24 vdc power supply lulc15 218.00 canopen communication allows the tesys u starter to be connected to the network using the can open protocol advanced or multi-function control units (24 vdc only) and lu9bn11l or lu9mrl pre-wired connector requires separate 24 vdc power supply lulc08 218.00 beckoff communication allows the tesys ustarter to be connected to the network using the beckoff protocol advanced or multi-function control units (24 vdc only) and lu9bn11l or lu9mrl pre-wired connector requires separate 24 vdc power supply lulc14 218.00 profibus communication allows the tesys ustarter to be connected to the network using the profibus protocol advanced or multi-function control units (24 vdc only) and lu9bn11l or lu9mrl pre-wired connector requires separate 24 vdc power supply lulc07 218.00 devicenet ? communication allows the tesys u starter to be connected to the network using the device net protocol advanced or multi-function control units (24 vdc only) and lu9bn11l or lu9mrl pre-wired connector requires separate 24 vdc power supply lulc09 218.00 p communication capabilities can be integrated into existing automation architecture via a variety of protocols. q see 18-29 for placement on the power base. table 18.120: control circuit accessories f accessory applic ation technical data mounting catalog number $ price control circuit contact block switches control circuit power via lub ? handle (nec430-74 compliance) 5 amp at 600 vac 5 amp at 250 vdc side mounting to lub ? and lu2b ? only lua8e20 71.00 through-the-door operating mechanism use in enclosures 7.5 to 20 inches deep. use with lub ? only. ?? lu9ap00 125.00 operating handle (nema 12) use with lu9ap00 black / blue enclosure door lu9ap11 31.50 red / yellow enclosure door lu9ap12 31.50 control circuit filters use with electronic or triac output controllers up to 150 vac max. directly to coil terminals non-reversing lua4f11 39.30 reversing lua4f12 39.30 r see page 29 for placement on the power base. table 18.121: powersuite configuration software and accessories item a catalog number $ price b powersuite software vw3a8104 225.00 pc connection kit vw3a8106 113.00 pocket pc connection kit vw3a8111 143.00 a for complete details on all components in cluded with each item, refer to catalog # 8502ct0201 . b items under discount schedule cp4c. table 18.122: gv2 cabling accessories?bus bars description applicat ion pitch standard pack catalog number $ price each 3-pole, 63 a bus bar for feeding 2 gv2 starters or tesys u 45 54 72 1 1 1 gv2g245 gv2g254 gv2g272 23.30 23.30 23.30 for feeding 3 gv2 starters or tesys u 45 1 gv2g345 28.70 54 1 gv2g354 28.70 for feeding 4 gv2 starters or tesys u 45 54 72 1 1 1 gv2g445 gv2g454 gv2g472 34.20 34.20 34.20 for feeding 5 gv2 starters or tesys u 54 1 gv2g554 34.20 as-interface modbus devicenet profibus canopen i11 discount schedule
www.schneider-electric.us 18 iec contactors and starters 18-32 ? 2009 schneider electric all rights reserved soft starters atsu01 altistart ? drive and tesys ? u simple motor starter refer to catalog 8502ct9901 altistart drive and te sys u motor starter atsu01?? e231693 ccn nldx lr96921 class 3211 06 table 18.123: soft start/soft stop unit for 0.75 to 15 kw motors (can be combined with the tesys u starter) motor starter motor power (1) nominal current part number $ price 230 v 460 v hp hp a 3-phase supply voltage: 200 ... 480 v 50/60 hz 12 6 atsu01n206lt 133.00 1.5 3 259 atsu01n209lt 152.00 37.512 atsu01n212lt 175.00 510 22 atsu01n222lt 219.00 7.5 15 10 20 32 atsu01n232lt 300.00 a standard motor power ratings, hp power ratings indicated according to standard ul 508. table 18.124: accessories description used for starter reference $ price power connector between at s u 0 1 n 2 ?? lt and tesys u at s u 0 1 n 2 ?? t vw3g4104 10.00 table 18.125: tesys u starter and soft start unit combinations motor power soft starter tesys u voltage power base control unit b 200 v 460 v hp hp 1 2 atsu01n206lt lub 12 luc ? 05bl 1.5 3 atsu01n206lt luc ? 12bl 2 5 atsu01n209lt luc ? 12bl 3 ? atsu01n212lt luc ? 12bl ? 7.5 atsu01n212lt luc ? 18bl 5 10 atsu01n222lt luc ? 18bl 7.5 15 atsu01n222lt lub 32 luc ? 32bl 10 20 atsu01n232lt luc ? 32bl b depending on the configuration of the chosen tesys u starter, replace the ? with ?a? for standard, ?b? for advanced, and ?m? for multifunction. see page 18-28 for a complete list of available control units. control voltage must be 24 vdc. cp1g i11 discount schedule
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-33 starters tesys ? gv2 and gv3 manual starter and protector refer to catalog 2520ct0001 the gv family of products are 3-pol e, horsepower rated, ul 508 listed, manual starters. they include a manual disconnect, class 10 ambient-com pensated thermal overload relay, and an in stantaneous magnetic trip mechanism in one compact unit. any gv manual starter can be used alone for local manual cont rol of a motor with indivi dual full-load currents up to 220 amps. the gv family of products may also be used in group mo tor installations in accordance with national electric code article 430-53. group motor installa tions give you greater panel density for smaller size and require fewer parts and less wiring necessary for installation when compared to conv entional panel designs. the gv2p and gv3p products also have an additional ul 508 type e rating as a stand alone self-protected manual combination starter. the ul 508 type e rating requires the addi tion of line side insulating barrier gv2gh7 for the gv2p or part number gv3g66 for the gv3p. the gv2p and the gv3p self-protected manual combination starter may also be combined with specific size contactors from the lc 1d product family for a ul 508 type f combination starter construction. these products have ul-listed short circuit current ra ting from 10?100 ka depending on application size and voltage. see www.us.telemecanique.com for more information. how to order to order the basic motor starter, select the model number (gv2me??, gv2p??, or gv3p??) with the appropriate thermal setting from the table below. the thermal trip range and setting should be determined from the motor nameplate full- load current. specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-36 accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-34 to 18-35 dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-52 to 18-55 gv2me gv3p e164864 ccn nlrv lr81630 class 3211 05 gv2p21 with gv2gh7 installed table 18.126: thermal setting (a) maximum horsepower ratings group motor applications gv2/3m push button gv2/3p rotary handle 1? 3? 115 v hp 230 v hp 200 v hp 230 v hp 460 v hp 575 v hp max. fuse or circuit breaker catalog number $ price catalog number $ price 0.11?0.16?????? 450 a gv2me01 a 159. gv2p01 212. 0.16?0.25?????? 450 a gv2me02 a 159. gv2p02 212. 0.25?0.40?????? 450 a gv2me03 a 159. gv2p03 212. 0.40?0.63?????? 450 a gv2me04 a 180. gv2p04 233. 0.63?1????0.50.5 450 a gv2me05 a 180. gv2p05 233. 1?1.6 ? 0.1 ? ? 0.75 1 450 a gv2me06 a 180. gv2p06 233. 1.6?2.5 ? 0.667 0.5 0.5 1 1.5 450 a gv2me07 a 180. gv2p07 233. 2.5?4 1/8 0.333 0.75 1 2 3 450 a gv2me08 a 180. gv2p08 233. 4?6.3 1/4 0.5 1.5 1.5 3 5 450 a gv2me10 a 180. gv2p10 233. 6?10 0.5 1.5 2 3 5 7.5 450 a gv2me14 a 180. gv2p14 233. 9?14 0.75 2 3 3 10 10 450 a gv2me16 a 224. gv2p16 278. 13?1813551015 450 a gv2me20 a 224. gv2p20 278. 17?23 1.5 3 5 7.5 15 20 450 a gv2me21 a 224. gv2p21 278. 20?25 2 3 5 7.5 15 20 450 a gv2me22 a 224. gv2p22 278. 24?32 2 5 10102030 450 a gv2me32 224. gv2p32 278. 9?13 0.5 1.5 3 3 7.5 10 ? ? gv3p13 404. 12?18 0.75 2 5 5 7.5 10 ? ? gv3p18 404. 17?25 1.5 3 7.5 7.5 15 20 ? ? gv3p25 404. 23?32 2 3 10 7.5 20 25 ? ? gv3p32 404. 30?40 3 5 10102530 ? ? gv3p40 504. 37?50 3 7.5 15 10 30 40 ? ? gv3p50 504. 48?65 3 10 20 15 40 50 ? ? gv3p65 504. a for spring terminals add 3 to the catalog number, for example, gv2me013. gv2me32 is not available with spring terminals. table 18.127: thermal setting (a) maximum horsepower ratings 1? 3? toggle operator 115 v hp 230 v hp 200 v hp 230 v hp 460 v hp 575 v hp standard interrupt high interrupt catalog number $ price catalog number $ price 12?20 ? ? ? 5 10 15 gv7re20 417. gv7rs20 813. 15?25 ? ? ? 7.5 15 20 gv7re25 417. gv7rs25 813. 25?40 ? ? ? 10 30 30 gv7re40 417. gv7rs40 813. 30?50 ? ? ? 15 30 40 gv7re50 417. gv7rs50 813. 48?80 ? ? ? 30 60 75 gv7re80 417. gv7rs80 813. 60?100 ? ? ? 30 75 100 gv7re100 456. gv7rs100 891. 90?150 ? ? ? 50 100 150 gv7re150 502. gv7rs150 978. 132?220 ? ? ? 75 150 200 gv7re220 502. gv7rs220 978. new! gv7re20 i11 discount schedule
www.schneider-electric.us 18 iec contactors and starters 18-34 ? 2009 schneider electric all rights reserved starters accessories tesys ? gv2 and gv3 manual starters and protectors refer to catalog 2520ct0001 gvau116 table 18.128: voltage trips only one trip or fault signaling contac t can be installed per gv2/gv3 device. description characteristics vo ltage frequency catalog number a $ price voltage trips gv2 & gv3p undervoltage or shunt trip (external mount, 1 block right side only) 24 v 50 hz gva ? 025 81.00 60 hz gva ? 026 48 v 50 hz gva ? 055 60 hz gva ? 056 100?110 v 50/60 hz gva ? 107 110?115 v 50 hz gva ? 115 60 hz gva ? 116 120?127 v 50 hz gva ? 125 127 v 60 hz gva ? 115 200 v 50 hz gva ? 207 200?220 v 60 hz gva ? 207 220?240 v 50 hz gva ? 225 60 hz gva ? 226 380?400 v 50 hz gva ? 385 60 hz gva ? 386 415?440 v 50 hz gva ? 415 415 v 60 hz gva ? 416 440 v 60 hz gva ? 385 480 v 60 hz gva ? 415 500 v 50 hz gva ? 505 600 v 60 hz a to order an under voltage trip: replace the bullet ( ? ) with a u , example: gvau025 . to order a shunt trip: replace the bullet ( ? ) with an s , example: gvas025 . gvae11 gvad0101 gvan11 table 18.129: auxiliary contact blocks description mounting location max. no. of blocks contact type sold in lots of catalog number $ price instantaneous auxiliary contacts gv2 + gv3p front bg 1 n.o. or n.c. c 1 gvae1 21.80 n.o. + n.c. 10 gvae11 e 35.70 n.o. + n.o. 1 gvae20 e 35.70 left hand side 2 n.o. + n.c. 1 gvan11 e 35.70 n.o. + n.o. 1 gvan20 e 35.70 fault signaling contact + instantaneous auxiliary contact gv2 + gv3p left hand side d 1 n.o. (fault) + n.o. 1 gvad1010 54.00 n.o. (fault) + n.c. 1 gvad1001 54.00 n.c. (fault) + n.o. 1 gvad0110 54.00 n.c. (fault) + n.c. 1 gvad0101 54.00 short circuit signaling contact gv2 + gv3p left hand side 1 spdt 1 gvam11 35.70 b mounting of a gvae contact block or a gv2ak00 visible isolation block on gv2p . c choice of n.c. or n.o. contact operation, depending on which way the reversible block is mounted. d the gvad is always mounted next to the starter. e for spring terminals add 3 to the catalog number. example: gvae113 f one trip or one fault signaling can be fitted per gv3. g cannot be used with gv2gh7 insulator. table 18.130: voltage trips?technical data (gv2au, gv2as) rated voltage?660 vac model inrush sealed pick-up voltag e drop-out voltage operating time h gvau 12 va / 8 w 3.5 va / 1.1 w 0.8 to 1.1 0.35 to 0.7 10 to 15 ms gvas 14 va / 10.5 w 5 va / 1.6 w 0.7 to 1.1 0.2 to 0.75 10 to 15 ms h from the loss of voltage at the trip terminals to the opening of the starter contacts. table 18.131: gv3p accessories description for gv3p ca talog number $ price set of 3-pole 115 a busbars (tap-offs: 2, pitch: 64 mm) gv3p ?? gv3g264 25.00 set of 3-pole 115 a busbars (tap-offs: 3, pitch: 64 mm) gv3p ?? gv3g364 45.00 cover ?larger spacing? ul 508 type e (only one cover required on supply side) gv3p ?? gv3g66 18.00 ip 20 cover (two covers required per starter) gv3p ?? lad96570 12.00 padlocking device for use with up to 4 padlocks (not supplied) ? 6 mm shank maximum gv3p ?? gv3p ??? gv2v03 15.00 new! cp10 i11 discount schedule
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-35 starters accessories tesys ? gv7 manual starters and protectors refer to catalog 2520ct0001 dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-52 to 18-55 gv7ae11 table 18.132: auxiliary contact blocks (auxiliary co ntact functions depends on location inside the device) description mounting lo cation max. no. of blocks cont act type catalog number $ price standard instantaneous inside device 2 per device n.o. + n.c. gv7ae11 35.70 trip indication 1 per device n.o. + n.c. fault indication 1 per device n.o. + n.c. low level instantaneous inside device 2 per device n.o. + n.c. gv7ab11 35.70 trip indication 1 per device n.o. + n.c. fault indication 1 per device n.o. + n.c. gv7as055 gv7ad111 table 18.133: voltage trips description mounting locatio n max. no. of blocks voltage catalog number $ price undervoltage trip inside device 1 per device 48 vac 50 hz gv7au055 64.00 110?130 vac 50/60 hz gv7au107 200?240 vac 50/60 hz gv7au207 380?440/480 vac 50/60 hz gv7au387 525 vac 50 hz gv7au525 shunt trip inside device 1 per device 48 vac 50 hz gv7as055 64.00 110?130 vac 50/60 hz gv7as107 200?240 vac 50/60 hz gv7as207 380?440/480 vac 50/60 hz gv7as387 525 vac 50 hz gv7as525 fault indication inside device 1 per device 24?130 gv7ad111 72.00 110?415 gv7ad112 gv7ac01 gv7ap03 gv7re20 gv7ac021 gv7v01 table 18.134: wiring accessories description application c atalog number $ price box lugs sold in lots of 3 for gv7r ? 20?150 i gv7ac021 19.70 each sold in lots of 3 for gv7r ? 220 i gv7ac022 24.90 each phase barriers, bus bars & shrouds terminal extension kit increases center distance between phases to 45 mm gv7ac03 46.70 terminal shroud kit covers terminal connections for touch safe protection gv7ac01 41.90 phase barriers provides maximum phase separation at connection points gv7ac04 31.10 insulating barriers provides insulation between connectors and backplate gv7ac05 24.90 busbars and covers connect to lc1f115?185 contactor gv7ac06 46.70 connect to lc1f225?265 contactor gv7ac07 46.70 operating handles and accessories black rotary operating handle with black legend plate (mounts directly on device) gv7ap03 86.00 red rotary operating handle with yellow legend plate (mounts directly on device) gv7ap04 86.00 conversion accessory to mount device directly on panel door gv7ap05 14.00 black rotary operating handle with black legend plate and extension kit (185?600 mm) gv7ap01 102.00 red rotary operating handle with yellow legend plate and extension kit (185?600 mm) gv7ap02 102.00 padlocking device for toggle handle (max. 38 mm padlocks) gv7v01 14.00 i wire size: gv7ac021?#14?3/0; gv7ac022?#14?350 kcmil. i11 discount schedule
www.schneider-electric.us 18 iec contactors and starters 18-36 ? 2009 schneider electric all rights reserved starters accessories tesys ? manual starters and protectors ls1 fuseholders refer to catalog 2502ct0001 ? 45 mm wide (same dimensions as gv2me) ? available with screw clamp and spring type terminals ? mounts directly to lc1d09?d32 contacto rs (with use of gv2af3 or gv2af4) ? meets application needs for fusible starter ? uses gv2ae instantaneous contact blocks to open control circuits ? din rail mounted ls1d30 table 18.135: description fuse type dimensions use in catalog number $ price in mm spring terminals, 3-pole cc, ktk-r 0.41 x 1.5 10.3 x 38 us markets ls1d303 86. screw clamp terminals, 3-pole cc, ktk-r 0.41 x 1.5 10.3 x 38 us markets ls1d30 86. spring terminals, 3-pole am, gg 0.39 x 1.5 10 x 38 european markets ls1d323 101. screw clamp terminals, 3-pole am, gg 0.39 x 1.5 10 x 38 european markets ls1d32 86. auxiliary main pole adder am, gg 0.39 x 1.5 10 x 38 european markets la8d324 a 65. a can be mounted on left-hand or right-hand side of the 3-pole ls1d32 block. table 18.136: specifications ty p e ls1d30, ls1d303 ls1d32, ls1d323, ls1dt32 max. voltage 600 v 3 phase max. current 30 a conforming to standards iec 60947-1, 60947-2, 60947-4-1, en60204, bs4841, ul 508, csa 222.2 no. 14, nfc 63-650, 63-120, 79-130, vde 0113, 0660 product approvals ul, csa bv protective treatment ?th? ?th? ambient air temperature ?operation -58 to 158 o f (-50 to +70 o c) wiring number of conductors and cr oss sectional area (c.s.a.) max. min. solid cable 2?#8 awg (2?6 mm 2 ) 2?#16 (2?1 mm 2 ) flexible cable without cable end 2?#8 awg (2?6 mm 2 ) 2?#14 (2?1 mm 2 ) flexible cable with cable end 2?#10 awg (2?4 mm 2 ) 2?#16 awb (2?1 mm 2 ) resistance to mechanical impact conforming to iec 60947-1 7-1-6 0.5 j tightening torque 15 in-lb (1.7 n?m) sensitivity to phase failure no table 18.137: specifications operating positions: shock resistance?30 g (conforming to iec 600 68-2-27) vibration resistance?5 g (5 to 150 hz) (iec 600 68-2-26) ambient temperature: -40 to 176 o f (-40 to +80 o c) for storage -4 to 140 o f (-20 to +60 o c) open operation -4 to 104 o f (-20 to +40 o c) enclosed operation rated voltage?600 v rated thermal current?25 a (gv2), 63 a (gv3) mechanical life: gv2: 100,000 operations maximum operating life?25 operations per hour operating current of magnetic trip is approximately 13 times maximum thermal trip (non-adjustable setting) 3 0 3 0 90 90 file lr81630 class 3211 05 file e164864 cnn nlrv i11 discount schedule
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-37 starters accessories tesys ? gv2 manual starters and protectors refer to catalog 2520ct0001 gv2gh7 lad31 lad311 gv2af3 / gv2af4 table 18.138: gv2 mounting accessories description application standard pack b catalog number $ price each common mounting plate for gv2 plus any 3-pole lc1d09 thru lc1d25 contactor. (supplied with gv1g02 connector) 1 gk2af01 21.60 adapter plate for screw mounting of gv2m 10 gv2af02 7.10 combination block interconnect for gv2 plus any 3-pole lc1k or lp1k contactor 10 gv2af01 14.00 interconnect gv2 and lc1d09 thru d32 10 gv2af3 3.20 interconnect gv2 and lc1d09 thru d32 mounted on lad31 10 gv2af4 3.20 7.5 mm compensation plate to allow mounting of gv2m and gv2p on a common bus bar 10 gv1f03 5.40 mounting plate for mounting gv2me or gv2p and contactor lc1d09 thru d32 10 lad31 6.20 10 lad311 12.30 table 18.139: gv2 cabling accessories?bus bars description app lication pitch standard pack b catalog number $ price each 3-pole, 63 a bus bar for feeding 2 gv2 starters 45 54 72 1 1 1 gv2g245 gv2g254 gv2g272 23.30 23.30 23.30 for feeding 3 gv2 starters 45 1 gv2g345 28.70 54 1 gv2g354 28.70 for feeding 4 gv2 starters 45 54 72 1 1 1 gv2g445 gv2g454 gv2g472 34.20 34.20 34.20 for feeding 5 gv2 starters 54 1 gv2g554 34.20 table 18.140: gv2 other cabling accessories description application standard pack b catalog number $ price each terminal blocks top feed for use with bus bars 1 gv1g09 34.20 bottom feed, to be used with bus bars; can be fitted with gv1l3 current limiter 1 gv2g05 34.20 protective end cover to cover unused bus bar outlets 5 gv1g10 3.60 3-pole flexible connector for connecting a gv2 to an lc1d09 thru d25 contactor 10 gv1g02 14.30 conduit adapter (1?2" npt) 1 gv2ak1 16.20 incoming line insulator for gv2p when used in ul 508 type e applications a 10 gv2gh7 15.00 a cannot be used with front-mounted auxiliary contact block. table 18.141: gv2 other accessories description application standard pack b catalog number $ price each visible isolation block - gv2p front mount, 3-pole visible isolation on incoming side of gv2p 1 gv2ak00 71.40 current limiter - gv2m increases interr upt capacity when attached to gv2m 1 gv1l3 117.00 through-door operator - gv2p for operating gv2p through enclosure door (red handle, yellow legend plate) for nema 1 use. ip54 1 gv2ap02 135.00 table 18.142: gv2 enclosures description mounting rating catalog number $ price each enclosures for gv2m with or without accessories (maximum of 1 accessory on right and left) enclosures are not ul or csa listed. surface mount nema 1, ip41 ip55 gv2mc01 gv2mc02 54.00 78.00 flush mount nema 1, ip41 ip55 gv2mp01 gv2mp02 31.10 54.00 flush mount reduced width (max. of 1 accessory on right) nema 1, ip41 ip55 gv2mp03 gv2mp04 27.90 49.70 table 18.143: gv2 enclosures accessories description type standard pack b catalog number $ price each padlocking device for gv2m (when padlocked, starter is automatically in off position) 1 gv2v01 26.90 mushroom head stop push button (40 mm, red) c spring return 1 gv2k011 35.90 latching key release (ronis key no. 455) 1 gv2k021 104.00 turn to release 1 gv2k031 52.00 latching / padlockable turn to release 1 gv2k04 117.00 sealing kit for enclosures gv2mc01 and gv2mp01 10 gv2e01 18.00 pilot light (neon) 110 v green 10 gv2sn13 26.90 110 v red 10 gv2sn14 110 v orange 10 gv2sn15 110 v white 10 gv2sn17 220/240 v green 10 gv2sn23 220/240 v red 10 gv2sn24 220/240 v orange 10 gv2sn25 220/240 v white 10 gv2sn27 380/440 v green 10 gv2sn33 380/440 v red 10 gv2sn34 380/440 v orange 10 gv2sn35 380/440 v white 10 gv2sn37 b orders must specify multiples of quantities listed. c supplied with ip55 sealing kit. i11 discount schedule
www.schneider-electric.us 18 iec contactors and starters 18-38 ? 2009 schneider electric all rights reserved wiring, communications, and busbar system tesys ? contactors and motor protectors with spring terminals refer to catalog 8502ct0101 app2r4h1 table 18.144: splitter boxes a total of up to eight starters is permissible after extens ions. use multiple quantities of the same catalog number to create the desired line-up. description type of control-command connection on control system side no. of i/o per starter no. of starters per unit catalog number $ price 50 a power splitter box ? ? 2 lad322 52.00 4 lad324 93.00 50 a power and control splitter box 1 x he10 8i/8o 1i/1o 4 app2r4h1 124.00 1 x he10 16i and 1 x he10 8o 2i/1o 4 app2r4h2 124.00 via module app1c ??? a ? 2 app2r2e 124.00 4 app2r4e 124.00 as-i 2i/1o 2 app2r2as 124.00 1i/1o 4 app2r4as 124.00 a connection to an app1c ??? module via app2cx adaptor (lad35). lad35 table 18.145: power connection components for one starter description kit consists of: catalog number $ price assembly and power connection kit one lad31 plate for gv2me and two lad34 power connection modules lad351 21.00 reversing kit b one set of bus bars and one mechanical interlock lad32 20.70 b to create a tesys d reverser, use two lc1d contactors, one assembly and power connection kit, and one reversing kit. lad3b lad33 table 18.146: power connection accessories for one starter description max. connection cross-section use catalog number $ price upstream terminal block (50 a max) 16 mm 2 (6 awg) power supply for one or two power splitter boxes lad3b 83.00 downstream terminal block (50 a max) 6 mm 2 (10 awg) connection of motor cables lad331 5.00 app2d1? table 18.147: control connection module for one starter description d-line coil voltage type of coil control relay type of starter catalog number $ price control connection module (integrating contact block gvae20) 12?240 vac or 24?125 vdc electromechanical c non-reversing app2d1 41.40 reversing app2d2 72.00 24?48 vdc without relay d non-reversing app2d1d 31.10 reversing app2d2d 31.10 c relay supplied mounted on the front panel of the control connection. d the use of tesys d low consumption contactors is recommended. table 18.148: spare or replacement parts description type of control-command connection on control system side no. of i/o per starter no. of starters sold in lots of catalog number $ price plate for mounting a gv2me manual starter ? ? 110 lad31 6.20 110 lad311 12.30 power connection module ? ? 1 10 lad341 7.50 control-command splitter box (single, for mounting on a power splitter box) 1 x he10 8i/8o 1i/1o 4 1 app2r4h3 11.30 1 x he10 16i and 1 x he10 8o 2i/1o 4 1 app2r4h4 11.30 per module app1c ??? e ? 21 app2r2c 11.30 41 app2r4c 11.30 as-interface 2i/1o 2 1 app2r2a 11.30 1i/1o 4 1 app2r4a 11.30 replacement electromechanical relay (for control connection module) ? 1 10 app2er 7.50 e connection to an app1c ??? module via app2cx adaptor (lad35). i11 discount schedule
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-39 busbar accessories tesys ? ak5 panel busbar system refer to catalog 8502ct0101 the ak5 pre-fabricated bus bar system provides a quick and easy method of mounting control devices. all components are finger safe, ul listed, csa approved and ce marked. although the ak5 system can be screw mounted onto any type of support, it must be mounted on the am1dl201 din rail when component mounting plates incorporating a tap- off are used. when using tap-offs , the nominal operating current of the bus bar (160 amperes @ 35 o ) must not be exceeded. ak5jb143 table 18.149: 160 ampere three phase busbar system maximum number of mounting plates length catalog number $ price tap-off standard width plate extension plate in mm in mm in mm 1.42 36 2.13 54 2.80 71 in mm 6 4 2 13.39 344 ak5jb143 210.00 9 6 3 17.64 452 ak5jb144 266.00 12 8 4 21.85 560 ak5jb145 286.00 15 10 5 26.05 668 ak5jb146 345.00 24 16 8 38.69 992 ak5jb149 393.00 27 18 9 42.90 1100 ak5jb1410 540.00 ak5pa231 ak5pa232s table 18.150: mounting plate tap-off plugs into busbar mounted on am1dl201 din rail. width thermal current amperes application catalog number $ price in mm 2.13 54 25 a lus or lub 12 and 32 & gv2 ak5pa231 98.00 2.13 54 25 a gv2 & contactor ak5pa232 120.00 4.25 108 25 a gv2 & reversing contactor ak5pa232s 206.00 ak5pc33 table 18.151: bus tap-off plugs into busbar for wiring to a separately mounted device. width thermal current amperes length of leads catalog number $ price in mm in mm 1.42 36 32 a 9.84 250 ak5 pc33 23.00 1.42 36 32 a 39.37 1000 ak5 pc33l 37.80 table 18.152: extension plates used to mount wider components. bolt to standard mounting plates (after din rails are removed). width application catalog number $ price in mm 2.80 71 gv & reversing contactor ak5pe27 26.30 table 18.153: mounting rail must be used for mounting plates with tap-offs. description depth length catalog number $ price mm mm 75 mm omega rail 15 2000 am1dl201 41.10 table 18.154: approvals: iec 439, ul, csa, dnv, lros file e161251 ccn nmtr file lr 89150 class 6228-01 am1dl201 i11 discount schedule
www.schneider-electric.us 18 iec contactors and starters 18-40 ? 2009 schneider electric all rights reserved dimensions tesys ? d contactors, ac coil refer to catalog 8502ct9901 table 18.155: tesys d contactors ac control circuits lc1d09 to d18 (3-pole) and lc1dt12 to lc1dt40 (4 pole) lc1d25 to d38 (3-pole) lc1 d09 to d18 d093 to d18 d099 to d189 d25 to d38 d183 and d323 dt20 and dt25 dt203 and dt253 dt32 to dt40 dt323 and dt403 in (mm) in (mm) in (mm) in (mm) in (mm) in (mm) in (mm) in (mm) in (mm) b ac coil, without add-on accessories 3.03 (77) 3.89 (99) 3.14 (80) 3.36 (85) 3.89 (99) 3.34 (85) 3.89 (99) 3.58 (91) 4.13 (105) dc coil b1 ac coil, with lad4bb b 3.70 (94) 4.21 (107) 3.75 (95.5) 3.85 (98) 4.21 (107) 3.85 (98) ? ? ? ac coil, with la4d*2 b 4.33 (110) a 4.84 (123) a 4.30 (111.5) a 4.48 (114) a 4.84 (123) a 4.48 (114) ? ? ? ac coil, with la4df, dt b 4.68 (119) a 5.19 (132) a 4.76 (120.5) a 4.84 (123) a 5.19 (132) a 5.02 (129) ? ? ? ac coil, with la4dr, dw, dl b 4.96 (126) a 5.67 (139) a 5.0 (127.5) a 5.11 (130) a 5.47 (139) a 7.48 (190) ? ? ? c ac coil, without cover or add-on blocks 3.30 (84) 3.30 (84) 3.30 (84) 3.54 (90) 3.54 (90) 3.54 (90) 3.54 (90) 3.85 (98) 3.85 (98) ac coil, with cover, without add-on blocks 3.38 (86) 3.38 (86) 3.38 (86) 3.62 (92) 3.62 (92) 3.62 (92) 3.62 (92) 3.93 (100) 3.93 (100) dc coil, without cover or add-on blocks 3.66 (93) 3.66 (93) 3.66 (93) 3.89 (99) 3.89 (99) ? ? ? ? dc coil, with cover, without add-on blocks 3.76 (95) 3.76 (95) 3.76 (95) 3.97 (101) 3.97 (101) 3.90 (99) 3.90 (99) 4.21 (107) 4.21 (107) c1 ac coil, with ladn or c (two or four contacts) 4.60 (117) 4.60 (117) 4.60 (117) 4.84 (123) 4.84 (123) 4.84 (123) 4.84 (123) 5.15 (13 1) 5.15 (131) dc coil, with ladn or c (two or four contacts) 4.96 (126) 4.96 (126) 4.96 (126) 5.19 (132) 5.19 (132) 4.84 (123) 4.84 (123) 5.15 (1 31) 5.15 (131) c2 ac coil, with lad6k10 5.07 (129) 5.07 (129) 5.07 (129) 5.31 (135) 5.31 (135) 5.31 (135) 5.31 (135) 5.62 (143) 5.62 (143) dc coil, with lad6k10 5.43 (138) 5.43 (138) 5.43 (138) 5.66 (144) 5.66 (144) 5.31 (135) 5.31 (135) 5.62 (143) 5.62 (143) c3 ac coil, with ladt,r,s 5.39 (137) 5.39 (137) 5.39 (137) 5.62 (143) 5.62 (143) 5.62 (143) 5.62 (143) 5.94 (151) 5.94 (151) ac coil, with ladt,r,s and sealing cover 5.55 (141) 5.55 (141) 5.55 (141) 5.78 (147) 5.78 (147) 5.78 (147) 5.78 (147) 6.10 (155) 6. 10 (155) dc coil with ladt,r,s 5.76 (146) 5.76 (146) 5.76 (146) 5.98 (152) 5.98 (152) 5.62 (143) 5.62 (143) 5.94 (151) 5.94 (151) dc coil with ladt,r,s and sealing cover 5.90 (150) 5.76 (146) 5.76 (146) 6.14 (156) 6.14 (156) 5.78 (147) 5.78 (147) 6.10 (155) 6.10 (15 5) a including lad4bb b not applicable to devices with dc coils table 18.156: ac coil lc1d40, d50, d65 (3p), lc1d65004 (4p) lc1d80004 (4p) lc1 d40a?d65a (3p), lc1 dt60a?dt80a (4p) ac or dc lc1 d40a?d65a dt60a?dt80a d40008 in (mm) in (mm) in (mm) a 2.17 (55) 2.76 (70) 3.35 (85) b1 with la4 d ? 2 ? ? 5.31 (135) with la4 db3 or lad 4bb3 5.35 (136) ? ? with la4 df, dt 6.18 (157) ? 5.59 (142) with la4 dm, dw, dl 6.54 (166) ? 5.91 (150) c without cover or add-on blocks 4.65 (118) 4.65 (118) 4.92 (125) with cover, without add-on blocks 4.72 (120) 4.72 (120) ? c1 with lad n (1 contact) ? ? 5.47 (139) with lad n or c (2 or 4 contacts) 5.91 (150) 5.91 (150) 5.79 (147) c2 with lad 6k10 or la6 dk 6.42 (163) 6.42 (163) 6.26 (159) c3 with lad t, r, s 6.73 (171) 6.73 (171) 6.57 (167) with lad t, r, s and sealing cover 6.89 (175) 6.89 (175) 6.73 (171) b c c1 c2 c 3 1.77 (lad 8 ) b 1 1.7 3 la4 . 3 9 10 44 45 .51 1 3 minim u m electric a l cle a r a nce b c c1 c2 c 3 . 3 9 10 minim u m electric a l cle a r a nce ac coil dc coil b 1.77 c . 3 9 10 c1 c2 c 3 45 minim u m electric a l cle a r a nce b c . 3 9 10 c1 c2 c 3 minim u m electric a l cle a r a nce x cept la1dn10, dn01 = 1 3 6 +4 mm with le a d s e a ling device (la2, la 3 , la6 dk1) 5.75 * 146 (la1) 6.50 ** 165 4.49 114 5.00 127 5.20 1 3 2 5.59 142 (la4 df, dt) 5.91 150 (la4 dm, dr, dw, dz) 2.95 75 .51 1 3 .51 1 3 (la 8 ) (la 8 ) (la4 da2, de2) ( 3 p) 3 . 3 4 8 5 (4p) (la2, la 3 , la6 dk2) 6.02 * 15 3 (la1) 6.77 ** 172 4.92 125 5.00 127 * except la1dn10, dn01 = 1 3 6 ** +4 mm with le a d s e a ling device 5.51 140 5.79 147 (la4 df, dt) 6.1 8 157 (la4 dm, dr, dw, dz) (la4 da2, de2) 3 . 3 4 8 5 .51 1 3 (la 8 ) .51 1 3 (la 8 ) ( 3 p) 3 .7 8 96 (4p) 4.61 117 4.80 122 a (lad 8n) (lad 8n) 0.49 12.5 c1 c2 c3 b1 0.47 12 c 0.49 12.5 minimum electrical clearance
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-41 dimensions tesys ? d contactors, dc coil refer to catalog 8502ct9901 table 18.157: dc coil lc1d40, d50, d65 (3p), lc1d650004, (4p) lc1d80 (3p), lc1d800004(4p) lc1d115, d150 panel mounted with 1/4? screws lc1 d115 d1156 d150 d1506 c 5.12 (132) 4.53 (115) 5.12 (132) 4.53 (115) g (3-poles) 3.78/4.33 (96/110) 3.78/4.33 (96/110) 3.78/4.33 (96/110) 3.78/4.33 (96/110) g (4-poles) 5.12/5.67 (130/144) 5.12/5.67 (130/144) ? ? lc1d115, d150 lc1 c a d115, d150 5.12 (132) 4.72 (120) d115004 5.12 (132) 6.10 (155) d1156, d1506 4.53 (115) 4.72 (120) d1150046 4.53 (115) 6.10 (155) lr2d4 bimetallic overload relay direct mounting beneath contactors lc1d115 and d150 lr9d solid-state overload relay direct mounting beneath contactors lc1d115 and d150 35 mm din rail dimensions 35 mm din rail dimensions am1dp200 and dr200 am1de ??? and ed ??? am1dp200 and dr200 am1de ??? and ed ??? d 0.10 (2.5) .41 (10.5) d 0.10 (2.5) .41 (10.5) note: all dimensions are in inches (mm). 2.95( 3 p) 3 . 3 4(4p) 75 8 5 5.20 (la4 dc 3 ) 1 3 2 5.47 (la4 df, dt) 1 3 9 5.75 (la4 dm, dr, dw, dz) 146 .47 12 6.7 3 171 4.96 126 8 .0 3 * (la1) 204 8 .7 8 d (la6 dk2, la2, la 3 ) 22 3 * except la1dn10, dn01 = 1 3 6 d + 4 mm with le a d s e a ling device minimum electrical clearance 8 .27 * (la1) 210 9.02 d (la6 dk 3 , la2, la 3 ) 22 3 4.96 126 7.1 3 1 8 1 .47 12 * except la1dn10, dn01 = 14 3 d + 4 mm with le a d s e a ling device 3 . 3 4 ( 3 p) 3 .7 8 (4p) 8 596 5.51 (la4 dc 3 ) 140 5.79 (la4 df, dt) 147 6.06 (la4 dm, dr, dw, dz) 154 minimum electrical clearance 130 5.12 = = 158 6.22 cg = = 6.22 158 c a 5.91 q (la1) 150 6.10 (la6-dk20) 155 6.61 c (la2, la3) 168 6.85 (la4d?2, d?3) 174 7.28 (df, dt) 185 7.40 (dm, dr, dw, dl) 188 la8 la4 a with 2 or 4 contacts. b + 4 mm with sealing cover. 5.20 132 d 4.72 120 10.51 267 5.91 150 7.44 189 5.20 132 4.72 120 d 6.85 174 10.04 255 5.35 136
www.schneider-electric.us 18 iec contactors and starters 18-42 ? 2009 schneider electric all rights reserved dimensions tesys ? f contactors refer to catalog 8502ct9901 lc1f115 to f330 lc1f400 to f500 all dimensions shown in mm. to convert to inches divide by 25.4. l c b b 2 = = x1 ( s ee t ab le 1 8 .15 8 ) a a protective cover type la9f70 ? . s s1 qp p q1 a f m c z = = g1 gy j j1 b1 = = table 18.158: lc1 f115 f150 f185 f265 f330 3-pole 4- pole 3- pole 4-pole 3- pole 4- pole 3- pole 4- pole 3- pole 4- pole a 163.5 200.5 163.5 200.5 168.5 208.5 201.5 243.5 213 261 b 162 162 170 170 174 174 203 203 206 206 b1 137 137 137 137 137 137 145 145 145 145 b2 265 265 301 301 305 305 370 370 375 375 c165 b 165 b 165 b 165 b 176 176 207 207 219 219 f 131 131 131 131 130 130 147 147 147 147 g 106 143 106 143 111 151 142 190 154.5 202.5 g1 80 80 80 80 80 80 96 96 96 96 j 106 106 106 106 106 106 106 106 106 106 j1 120 120 120 120 120 120 120 120 120 120 l 107 107 107 107 113.5 113.5 141 141 145 145 m 147 147 150 150 154 154 178 178 181 181 p 373740 40 404048484848 q29.529.526.526 292939344343 q1 60 60 57.5 55.5 59.5 59.5 66.5 66.5 74 74 s 151520 20 202025252525 s1 27 27 34 34 34 34 38 38 44.5 44.5 y 444444 44 444438383838 z 13.5 13.5 13.5 13.5 13.5 13.5 21.5 21.5 20.5 20.5 b +6 mm with time delay block (for f115 and f150). c optimal terminal shroud note: f = minimum distance required for coil removal. table 18.159: voltage in v 220/380 415/440 500 660 1000 lc1f115, f150 20 25 30 40 20 lc1f1852025304030 lc1f2652025405040 lc1f3302535405050 note: x1: minimum clearance according to the operational voltage and the breaking capacity. 2.20 56 x1 c l 8.23 209 b b2 = = e (see table 18.160) s 1.49 38 m10 x 30 dia. q pp q1 a f m 8 x 8.5 dia. g .92 23.5 g1 j 4.7 120 7.09 180 = = = = dual dime n s ion s : inche s millimeter s table 18.160: lc1 f400 f500 2-pole 3-pole 4-pole 2-pole 3-pole 4-pole a 213 213 261 233 233 288 b 206 206 206 238 238 238 b2 375 375 375 400 400 400 c 213 213 213 226 226 226 f 119 119 119 141 141 141 g d 80 80 80 80 80 140 g min. 66 66 66 66 66 66 g max. 102 102 150 120 120 175 g1 d 170 170 170 170 170 230 g1 min. 156 156 156 156 156 156 g1 max. 192 192 240 210 210 265 d supplied j 19.5 19.5 67.5 39.5 39.5 34.5 l 145 145 145 146 146 146 m 181 181 181 208 208 208 p4848 48 55 55 55 q6943 43 76 46 46 q1 96 74 74 102 77 77 s2525 25 30 30 30 e protective cover. note: f = minimum distance required for coil removal. table 18.161: voltage in v 220/230 415/440 500 660 1000 lc1f400 30 40 40 50 60 lc1f500 40 45 50 60 60 note: x1: minimum clearance according to the operational voltage and the breaking capacity.
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-43 lc1f630 and lc1f800 lc1f780, f7804 lc1f780 mounting lc1f7804 mounting 18.28 464 11.97 304 11.02 280 2.83 72 x1 9.84 250 6.10 155 7.76 197 = = c 10.39 264 1.57 40 2.52 64 6 x m12 x 45 a qq1 3.15 80 3.15 80 7.13* 181 2.38 60 g j1 7.09 180 = = 4 x dia. 10.5 mm dual dime n s ion s : inche s millimeter s lc1f630 a g supplied g min. g max. j1 q q1 in mm in mm in mm in mm in mm in mm in mm * = minimum distance required for coil removal. c protective terminal cover. 2 p 12.17 309 7.09 180 3.94 100 7.68 195 2.70 68.5 4.02 102 5.00 127 3 p 12.17 309 7.09 180 3.94 100 7.68 195 2.70 68.5 2.36 60 3.50 89 4 p 15.31 389 9.45 240 5.91 150 10.83 275 2.70 68.5 2.36 60 3.50 89 x1:minimum clearance according to the operational voltage and the breaking capacity. voltage in v 380 415/440 500 660 1000 x1 in mm 60 60 60 70 80 9.84 250 6.50 165 x1 11.02 280 17.08 434 = = 2.36 60 12 x m14 x 45 1.02 26 7.52 191 6.30 160 6.30 160 7.52 191 1.02 26 .86 22 13.70 348 15.74 400 27.64 f 702 33.93 a 862 7.20* 183 7.20* 183 x1: minimum clearance according to the operational voltage and the breaking capacity. voltage in v 380 415/440 660 1000 x1 in mm 90 100 120 120 f overall length (3 poles) a overall length (4 poles) *minimum distance required for coil removal. 3.50 90 9.45 240 9.45 240 5.20 132 5.00 127 7.09 180 5.00 127 6 x dia. 10.5 mm 3.50 90 9.45 240 7.48 190 9.45 240 5.00 127 7.09 180 5.00 127 8 x dia. 10.5 mm 4.00 102 dimensions tesys ? f contactors refer to catalog 8502ct9901
www.schneider-electric.us 18 iec contactors and starters 18-44 ? 2009 schneider electric all rights reserved dimensions tesys ? d reversing contactors refer to catalog 8502ct9901 lc2d09 to d32 lc2dt20 to dt60 2 x lc1dt20 to dt60 2 x lp1d40, d65, d80, d95 lc2 or 2 x lc1 abcg lc2 or 2 x lc1 abce1e2gg1 in (mm) in (mm) in (mm) in ( mm) in (mm) in (mm) in (mm) in (mm) in (mm) in (mm) in (mm) dt20 and dt25 3.54 (90) 3.34 (85) 3.54 (90) 3.14 (80) d40 to d65 7.16 (182) 5.0 (127) 7.4 (190) 1.19 (5) 0.43 (11) 2.2 (57) 3.8 (97) dt32 to dt60 3.54 (90) 3.58 (91) 3.85 (98) 3.14 (80) d80 and d95 8.14 (207) 5.0 (127) 8.4 (215) 0.51 (13) 0.78 (20) 3.7 (96) 4.3 (111) c, e2: includes cabling. c, e1 and e2: includes cabling. lc2d115 and d150 2 x lc1d115 and d150 panel mounted with 1/4? screw lc2 or 2 x lc1 (3-pole) a c e1 e2 g d115, d150 266 148 56 18 242/256 lc2 or 2 x lc1 (4-pole) a c e1 e2 g d115 334 148 ? 60 310/324 c, e1 and e2 includes cabling note: for dimensions of tesys f reversing contactors, please refer to catalog 8502ct9901 . 2xm0.16 g a = = 2.36 2.76 = = c b e2 60 70 2xm4 c be1 e2 g1 = = 6x?6.5 1.57 a == g 1.57 100 6x?0.26 8 .31 13 .51 40 40 3.94 110 4.33 6.22 158 e1 e2 c g a = = 5.12 130 = = dimensions shown in millimeters (mm 25.4 = inches)
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-45 dimensions tesys ? d overload relays refer to catalog 8502ct9901 lrd-01-35 independent mounting on 50 mm centers or on rail am1dp200 or de200 independent mounting on 110 mm centers remote tripping or electrical reset lrd, lr2d and lr9d ?reset? by flexible cable la7d305 and lad7305 mounting with cable straight mounting with cable bent a can only be mounted on rh side of relay lrd-01 to 35 c: up to 21.6in (550 mm) e: up to 0.79in (20 mm) lrd3 tt beneath lc1d tt a contactor separate mounting lr2d1, lr3d1 separate mounting at 50 mm (1.97?) centers or on am1dp200 or de200 rail lr2d2, lr3d2 separate mounting at 50 mm (1.97?) centers or on am1dp200 or de200 rail lr2d1, lr3d1 separate mounting at 110 mm (4.33?) centers lr2d2, lr3d2 separate mounting at 110 mm (4.33?) centers 1.77 45 .0 8 2 3 .15 8 0 1.50 38 3 .15 8 0 1.97 50 .20 5 lad7b106 1. 38 3 5 . 3 9 10 .24 6 .59 15 lad7b106 4. 33 110 = = 1. 8 1 46 = = 2x?0.26 2x?6.5 dx1ap25 3 .54 90 4.92 125 lad70 3 a 1.26 3 2 c e m10x0.04 e m10x1 185 7.28 55 2.17 123 4.84 lc1d pp a 116 4.57 87 3.43 55 2.17 3 . 8 6 9 8 1.4 8 4 3 .5 d 3 .11 79 la7-d1064 0.16 4 1.97/2.56 50/65 0. 3 1 8 0.67 17 2x ?0.1 8 2x?4.5 1. 38 3 5 = = 1.77 45 3 . 8 6 9 8 1.71 4 3 .5 d 3 .54 90 la7-d2064 0.12 3 0.51 1 3 0. 8 7 22 2x?0.1 8 2x?4.5 1.57 40 = = 2.17 55 1.97/2.56 50/65 4.92 125 4.25 10 8 la7d1064 dx1ap25 == 1.97 50 4. 33 110 = = 1. 8 1 46 2 x ?6.5 mm s crew s mo u nting hole s 4.25 10 8 4.92 125 la7d2064 1.97 50 4. 33 110 = = == 2.24 57 dx1ap25 mo u nting hole s 2 x ?6.5 mm s crew s
www.schneider-electric.us 18 iec contactors and starters 18-46 ? 2009 schneider electric all rights reserved dimensions tesys ? d thermal overload relays refer to catalog 8502ct9901 lrd-01-35 direct mounting beneath contactors with screw lrd-013-353 direct mounting beneath contactors with spring terminal connections lc1 ? d09?d18 d25?d38 lc1 ? d093?383 b 4.84 (123) 5.39 (137) b 4.84 (123) c see catalog 8502ct9901 pages 122, 123. c see catalog 8502ct9901 pages 122, 123. lrd-3 ??? direct mounting beneath contactors lc1-d40 to d95 and lp1-d40 to d80 am1 ? dl201 dl200 d 0.28 (7) 0.67 (17) bceg(3p)g(4p) ac control circuit lc1d40 4.37 (111) 4.69 (119) 2.85 (72.4) 0.18 (4.5) 0.51 (13) lc1d50 4.37 (111) 4.69 (119) 2.85 (72.4) 0.18 (4.5) ? lc1d65 4.37 (111) 4.69 (119) 2.85 (72.4) 0.18 (4.5) 0.51 (13) lc1d80 4.55 (115.5) 4.88 (124) 3.03 (76.9) 0.37 (9.5) 0.87 (22) lc1d95 4.55 (115.5) 4.88 (124) 3.03 (76.9) 0.37 (9.5) ? dc control circuit lc1d40, lp1d40 4.37 (111) 6.93 (176) 2.85 (72.4) 0.18 (4.5) 0.51(13) lc1d50 4.37 (111) 6.93 (176) 2.85 (72.4) 0.18 (4.5) ? lc1d65, lp1d65 4.37 (111) 6.93 (176) 2.85 (72.4) 0.18 (4.5) 0.51(13) lc1d80, d95, lp1d80 4.55 (115.5) 7.06 (179.4) 3.03 (76.9) 0.37 (9.5) 0.87(22) lrd4 ??? direct mounting beneath contactors lc1d115 and d150 lr9d direct mounting beneath contactors lc1d115 and d150 am1dl200 and dr200 am1de200 and ed ??? am1dp200 and dr200 am1de200 and ed ??? d 0.10 (2.5) 0.41 (10.5) d 0.10 (2.5) 0.41 (10.5) a for additional characteristics and catalog number information, see catalog 8502ct9901
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-47 dimensions tesys ? f overload relays refer to catalog 8502ct9901 lr9f5 ? 71 lr9f5 ? 57, f5 ? 63, f5 ? 67, f5 ? 69 common side view a terminal shroud la9f70 ? b 6.5 x 13.5 for lr9f5 ? 57 and 8.5 x 13.5 for lr9f5 ? 63, f5 ? 67, f5 ? 69 lr9f7 ? 75, f7 ? 79, f7 ? 81 lr9f7 ? 81 common side view (for mounting beneath lc1f630) p1 p2 lr9f7 ? 75 48 48 lr9f7 ? 79, f7 ? 81 55 55 c terminal shroud la9-f70 ? direct mounting beneath contactor lc1-f direct mounting beneath reversing contactors or star-delta contactors 2.99 76 1.57 40 1.57 40 3.78 96 1.97 50 1.97 50 2.36 60 2.80 71 .22 6 4x?5.5 4.53 115 .79 20 c b 4.72 120 2.36 60 1.97 50 1.97 50 2.80 71 ?1 1 4x?5.5 2.24 57 1.85 47 1.77 45 1.89 48 1.89 48 .98 25 4.53 115 .22 6 .11 3 .11 3 3.98 101 2.99 76 4.88 124 q a 4.29 109 .55 14 1.18 30 p2 p1 5.94 151 ?11 2.05 52 2.05 52 2.60 66 2.60 66 4x?5.5 2.76 70 .87 22 .24 6 3.23 82 5.39 137 .98 25 1.65 42 5.04 128 .24 6 1.77 45 f c 7.44 189 .79 20 7.87 200 3.15 80 3.15 80 7.60 193 9.02 229 3.03 77 3.03 77 2.44 62 ?13 1.57 40 1.57 40 h2 b h 3 h1 d h2 b h4 h 3 la7f40 p b us b a r d la7f40 e bus bar lc1 contactors with lr9 relays b h1 h2 h3 lc1 contactors with lr9 relays b h4 h2 h3 f115 f5 ? 57, f5 ? 63, f5 ? 67, f5 ? 69 240 30 76 120 f115 f5 ? 57, f5 ? 63, f5 ? 67, f5 ? 69 27960 76120 f150 f5 ? 57, f5 ? 63, f5 ? 67, f5 ? 69 246 30 76 120 f150 f5 ? 57, f5 ? 63, f5 ? 67, f5 ? 69 28360 76120 f185 f5 ? 57, f5 ? 63, f5 ? 67, f5 ? 69 250 30 76 120 f185 f5 ? 57, f5 ? 63, f5 ? 67, f5 ? 69 28560 76120 f225 f5 ? 71 273 40 76 120 f225 f5 ? 71 31980 76120 f7 ? 75, f7 ? 79 308 50 108.8 120 f7 ? 75, f7 ? 79 360 100 108.8 120 f265 f5 ? 71 279 40 76 120 f265 f5 ? 71 33290 76120 f7 ? 75, f7 ? 79 314 60 108.8 120 f7 ? 75, f7 ? 79 363 100 108.8 120 f330 f7 ? 75, f7 ? 79 317 60 108.8 120 f330 f7 ? 75, f7 ? 79 364 100 108.8 120 f400 f7 ? 75, f7 ? 79, f7 ? 81 317 60 108.8 180 f400 f7 ? 75, f7 ? 79, f7 ? 81 364 100 108.8 180 f500 f7 ? 75, f7 ? 79, f7 ? 81 346 70 108.8 180 f500 f7 ? 75, f7 ? 79, f7 ? 81 390 110 108.8 180 f630 f7 ? 81 510 110 108.8 180 f630 f7 ? 81 509 120 108.8 180 d relay mounting plate, see page 18-16. e connection accessories, see page 18-16.
www.schneider-electric.us 18 iec contactors and starters 18-48 ? 2009 schneider electric all rights reserved dimensions tesys ? d combination and non-combination starters refer to catalog 8502ct9901 nema 1 nema 12/3r non-combination st arter dimensions table 18.162: non-combination starter dimensions type 1 type 12/3r non-reversing reversing a b c d e f g h j k d e d09-32 ? 6.77 10.04 6.25 5.38 9.00 1?1.25 0.5?0.75 ? 1?0.25 0.5?0.75 5.38 11.37 d40-65 d09-32 8.66 10.83 7.21 7.25 9.75 1.25?1.5 0.5?0.75 1?1.25 1?0.25 0.5?0.75 5.38 12.15 d80 d40-80 10.63 13.98 7.21 9.22 12.94 1.25?1.5 0.5?0.75 1?1.25 1?1.25 0.5?0.75 5.38 15.30 note: all dimensions in inches. 7.50 191 provision for 1/4" screw .69 18 8.00 203 3.00 76 14.02 356 12.52 318 5.00 127 16.50 419 7.50 191 provision for 1/4" screw 10.00 254 18.00 457 r r d09-25 (fvnr) d09-40 (fvr); d32-40 (fvnr) 7.75 197 provision for 1/4" screw 19.63 499 5.00 127 provision for 1/4" screw 18.88 480 7.75 197 18.00 457 14.00 356 15.63 397 14.88 378 8.00 203 3.00 76 10.00 254 r r d09-25 (fvnr) d09-40 (fvr); d32-40 (fvnr) r .56 14 d d/2 provision for 1/4" screw c .75 19 fgh b e a .50 13 j k
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-49 dimensions tesys ? k contactors refer to catalog 8502ct9901 lr2k direct mounting under the contactor separate mounting with la7-k0064 terminal block on 35 mm rail (am1dp200 or am1de200) three-phase wiring scheme .31 8 2.56 65 1.77 45 4.57 116 2.28 58 1.97 50 4 x ?4 1.38 35 2.95 75 3 .09 (dp200) 7 8 3 . 38 (de200) 8 6 1.50 38 3 .15 8 0 1.77 45 1 3 5 2 4 6 95 97 96 98 a h test reset/stop internal links 1 3 5 13 a1 2 4 6 14 a2 2 4 6 97 95 98 96 ? km1 a2 a1 96 95 13 14 ? km1 o 95 96 lc1, lp1, lp4k mini-contactors on baseplate on am1dp200 or de200 rail ( 35 mm) on printed circuit board la1-k 2.24 57 1.22 31 2.28 58 4 x ?4 1.38 35 1.97 50 1.77 45 2.24 57 2.2 8 5 8 1.77 45 . 3 4 9 a1 a2 2.2 8 5 8 1.97 50 2.05 52 1.77 45 10 x ?.051 10 x ?1. 3 lc2, lc8, lp2, lp5k reversing mini-contactors on baseplate on am1dp200 or de200 rail ( 35 mm) on printed circuit board for reversing contactors or 2 mini-contactors side-by-side 8 x ?4 3.15 80 3.54 90 1.97 50 la1-k 1.22 31 2.28 58 2.24 57 2.24 57 2.2 8 5 8 3 .54 90 . 3 4 9 . 3 4 9 a1 a1 a2 a2 2.2 8 5 8 1.97 50 2.05 52 1.77 45 1.77 45 20 x ?.051 20 x ?1. 3 table 18.163: la2kt electronic time delay contact blocks on mini-contactors or reversing mini-contactors 1.34 34 1.50 38 1.06 27 dual dime n s ion s : inche s millimeter s 2.24 57 1. 3 4 3 4 2.2 8 5 8 la2-kt
www.schneider-electric.us 18 iec contactors and starters 18-50 ? 2009 schneider electric all rights reserved dimensions tesys ? u motor starters refer to catalog 8502ct0201 starter controllers non-reversing reversing note: minimum electrical clearance: x1 = 35 mm for ue = 440 v and 70 mm for ue = 500 and 690 v, x2 = 0 a maximum depth (with modbus ? communication module) 126 4.96 1 3 5 a 5. 3 1 154 6.06 x1 x1 45 1.77 x2 x2 126 4.96 1 3 5 a 5. 3 1 7 3 2. 8 7 3 0 1.1 8 ?4 .15 16 3 6.42 rail mounting screw mounting 224 8 . 8 2 45 1.77 120/125 4.72/4.92 2 33 9.17 29 1.14 ?4 .15 rail mounting screw mounting reversing block for mounting separately fr om power base rail mounting screw mounting 45 1.77 11 3 4.45 115 4.5 3 113 4.45 3 6 1.41 104 4.09 ?4 .15 limiter disconnector lualb1 a maximum depth (with modbus communication module) 45 1.77 9 3 3 .66 154 6.06 1 3 5 a 5. 3 1 door interlock mechanisms lu9ap00 door cut-out 50 8 20.01 11.5 .45 8 . 3 1 55 2.16 2 3 0 9.06 ?7 .27 = = = = 54 2.12 54 2.12 ?4 3 1.69 4x? 3 .5 .1 3 dual dime n s ion s : inche s millimeter s
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-51 dimensions altistart ? u01 and tesys ? u soft starters refer to catalog 8502ct9901 tesys u combination (non-reversing power base) and atsu 01n212lt mounting on (35mm) rail with vw3 g4104 connector tesys u combination (non-reversing power base) and atsu 01n222lt to atsu 01n232lt mounting on (35mm) rail with vw3 g4104 connector 150 5.91 2 8 4 11.1 8 45 1.77 9 0.354 3 14 12. 3 6 45 1.77 170 6.69 9 0.354 tesys u combination (non-reversing or reversing power base) and atsu 01n2206lt to atsu 01n212lt side-by-side mounting tesys u combination (non-reversing or reversing po wer base) and atsu 01n222lt to atsu 01n232lt side-by-side mounting vw3 g4104 po wer connector 99 3.9 135 5.31 154 6.06 72.2 2.84 9 124 4.88 0.354 99 3.9 135 5.31 72.2 2.84 154 6.06 9 0.354 44. 8 1.76 20 0.79 6 0.24 46.6 1. 83 2 8 1.10
www.schneider-electric.us 18 iec contactors and starters 18-52 ? 2009 schneider electric all rights reserved dimensions tesys ? manual starters and protectors refer to catalog 2520ct0001 gv2m gv2ad, am, an, au, as, ax gv2ae mounting of gv2m 8 9 66 44 16 11 .4 3 .6 3 1.7 3 2.60 3 .5 45 = = 44.5 1.75 1.77 9. 3 9. 3 8 1 1 8 . 3 7 . 3 7 .71 3 .19 block gv2ad, am, an block gv2au, a s , ax 15 .59 10 . 3 9 c 44.5 44.5 1.75 1.75 on 3 5 mm r a il c = 7 8 .5 mm ( 3 .09") on am1dp200 ( 3 5 x 7.5 mm) c = 8 6 mm ( 3 . 3 9") on am1de200, ed200 ( 3 5 x 15 mm) gv2p gv2ad, am, an, au, as, ax gv2ak00 mounting of gv2p 8 9 8 2 50 26 1.02 1.97 3 .2 3 3 .50 44.5 61 45 = = 1.75 1.77 2.40 .59 15 9. 3 9. 3 8 1 1 8 1 8 . 3 7. 3 7 3 .19 .71 block gv2ad, am, an block gv2au, a s , ax 9 8 14 .55 3 . 8 6 44.5 3 2 1.26 1.75 44.5 c 44.5 1.75 1.75 1 3 .5 8 4 .5 3 3 . 3 1 on 3 5 mm r a il c = 9 8 .5 mm ( 3 . 88 ") on am1dp200 ( 3 5 x 7.5 mm) c = 106 mm (4.17") on am1de200, ed200 ( 3 5 x 15 mm) gv2af4 + lad31 gv2p + gv2gh7 gv2p + gv2gh7 + tesys d contactor combination gv2me + tesys d range contactor combination gv2p + tesys d range contactor for ul 508 type e application for ul 508 type e application c1 c d1 d 45 1.77 b 45 1.77 b c1 c 10 3 4.07 44 1.7 3 191 7.50 3 .6 (91.4) 3 .6 (91.4) 3 . 8 (96.52) 3 . 8 (96.52) gv2me + lc2d09 to d18 lc2d25 and d32 g v2p + lc2d09 to d18 lc2d25 and d32 b 7.4 (188.6) 7.8 (199) b 6.61 (168.1) 7.9 (199.5) c1 3.6 (92.7) 3.9 (99) c1 4.6 (116.8) 4.6 (116.8) c 3.9 (98.2) 4.11 (104.5) c 4.8 (122.3) 4.8 (122.3) d1 3.9 (98.3) 3.9 (98.3) ? ? ? d 4.1 (103.8) 1.4 (103.8) ? ? ? surface mounting enclosure gv2mc0 ? flush mounting enclosure gv2mp0 ? (bracket cut-out) 147 8 4 3 . 3 1 5.79 9 3 3 .66 2x?5. 3 x6. 3 = 1 3 0 = = = 5.12 a a 4 knock-outs for 16 mm plastic cable gl ands or no. 16 conduit. 1...6 8 4 1 3 0.51 3 . 3 1 /0.04...0.24 b = b 1 = = 9 3 .5 = 106.5 3 .6 8 4.19 71 92. 8 6.5 2. 8 3 .65 0.25 gv2 b b1 in mm in mm mp01, mp02 5.51 140 5.00 127 mp03, mp04 5.24 133 4.61 117
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-53 dimensions tesys ? manual starters and protectors refer to catalog 2520ct0001 gv2m with gk2af01 and lc1k gv2m with gv2af01 and lc1k gv2m with gv2af01 and lc2k adapter plate gk2af01 dimensions in mm 79 3.11 45 152 1.77 6.0 152 90 3.54 6.0 24 55 45 135 9.5 .94 .37 1.77 2.17 5.31 45 35 54 105 5 35 ?5.5 5 1.38 1.38 1.77 2.13 4.13 .2 .2 .22 mounting external operator gv2ap0 ? door cut-out gv2m on panel with gv2af02 adapter plate 7.5 mm height compensation plate gv1f03 min.=150 7 53 65 5.2 = = 1.5...5 max.=290 2.56 2.1 5.91 /0.06...0.20 11.42 0.21 .276 54 = = = = 54 4x?3.5 0.14 ?43 1.7 2.13 2.13 80 3.15 50/60 4.2 35 1.38 1.97/2.36 .17 13 0.51 35 1.38 39 1.54 sets of bus bars, gv2g445, gv2g454, gv2g472 with terminal block gv2g05 sets of bus bars with terminal block gv1g09 sets of bus bars gv2g245, gv2g254, gv2g272 gv3 p dimensions mounting on rail am1 de200 or am1 ed201 x1 = electrical clearance (isc max) 40 mm for ue < 500 v, 50 mm for ue < 690 v blocks gv an pp , gv ad pp , gv am11 block gv3 au pp and gv3 as pp mounting on panel, using m4 screws mount ing on pre-slotted mounting plate am1 pa note: leave a space of 9 mm between 2 manual motor protectors: eith er an empty space or side-mounting add-on contact blocks. hor izontal mounting is possible: please consult your regional sales office. 63 2.5 l 3 .12 18 .71 p 45 1.8 30 1.2 l ip gv2g445 0.16 x 1.8" (4 x 45 mm) 7.0" (179 mm) 1.8" (45 mm) gv2g454 0.16 x 2.1" (4 x 54 mm) 8.1" (206 mm) 2.1" (54 mm) gv2g472 0.16 x 1.8" (4 x 45 mm) 10.2" (260 mm) 2.8" (72 mm) i gv2g245 0.08 x 1.8" (2 x 45 mm) 3.5" (89 mm) gv2g254 0.08 x 2.1" (2 x 54 mm) 3.9" (98 mm) gv2g272 0.08 x 2.8"(2 x 72 mm) 4.6" (116 mm) gv2g354 0.12 x 2.1" (3 x 54 mm) 6.0" (152 mm) 136 x1 x1 132 68 64 55 918 (2) (1) 144 68 64 136 3x?4 137,5 37,5 136 18,7 18,7 137,5 af1 ea4 183 16
www.schneider-electric.us 18 iec contactors and starters 18-54 ? 2009 schneider electric all rights reserved dimensions tesys ? gv7 manual starters and protectors 1 gv7r panel mounting flush mounting side by side 1. 38 3 5 1. 38 3 5 1. 38 3 5 = 4.92 125 = 2x?0.24 2x?6 = = 1.14 29 1.14 29 1. 8 5 47 3 .0 76 3 .46 88 3 .27 83 = = 4.25 10 8 4.25 10 8 = = 4.25 10 8 = = minimum clearance x1 x2 in (mm) in (mm) painted or insulated metal plate, insulation or insulated bar 0 (0) 1.18 (30) bare metal plate u < 440 v 0.20 (5) 1.38 (35) 440 v < u < 600 v 0.39 (10) 1.38 (35) u > 600 v 0.79 (20) 1.38 (35) note: minimum distance between 2 units mounted side by side = 0. motor controllers gv7r add-on auxiliary contacts, gv7ae11, gv7ab11 note: a self-adhesive label, supplied with the contact, can be affixed to the front face of the starter to allow personalized marking according to the function of the contact or contacts. gv7au ??? gv7as ??? gv7ad111, ad112 x1 x1 x2 x2 2/t1 4/t2 6/t 3 1/l1 3 /l2 5/l 3 21 24 22 11 14 12 91 94 92 8 1 8 4 8 2 9 8 97 50 m s ? ka1 2 3 24 1 3 14 ? ka1 d1 d4 c1 c2 9 8 97 50 m s ? km1 ? ka1 a1 a2 a1 a2 b1 ? ka1 21 22 9 8 97 50 m s
www.schneider-electric.us 18 iec contactors and starters ? 2009 schneider electric all rights reserved 18-55 dimensions tesys ? gv7 manual starters and protectors gv7ac03 spreaders cabling smooth terminals connectors a (in/mm) gv7r ? 0.77/19.5 gv7r ? 220 0.85/21.5 gv7ap03, gv7a04 direct rotary handle flush mounting 1.77 45 1.77 45 1.1 8 3 0 4.49 114 1.61 41 z x x 2.76 70 2.76 70 0.41 10.5 z z x 0.75 19 a 2. 8 7 7 3 1.77 45 6.10 155 4.76 121 0 i dd 60 60 2.17 55 3 .5 8 91 1.42 3 6 1.10 2 8 = = 3 . 8 2 97 1.14 29 1. 8 5 47 3 .0 76 3 .5 8 9
www.schneider-electric.us 18 iec contactors and starters 18-56 ? 2009 schneider electric all rights reserved dimensions tesys ? gv7 manual starters and protectors gv7ap03 or gv7ap04, gv7ap05 direct rotary handle front fuse ce nter enclosure viewed from top door cutouts require a minimum distance between the center of the manual motor protector and the door hinge point (h) of d >/= 3.94 in (100 mm) + (h x 5) gv7ap01, gv7ap02 extended rotary handle note: i: 7.28" (185 mm) minimum, 23.62" (600 mm) maximum. the shaft of the extended rotary handle gv7ap01 or gv7ap02 must be cut to length: i - 4.96" (126 mm) = = 3 .94 100 2. 3 2 59 3 .94 100 2.72 69 = 2.0 51 4.72 120 = 4.72 120 4.92 125 e 0. 3 6 9.25 0. 3 5 9 1.61 41 h d 2.95 75 = 60 0 i = 2.95 75 = = l 0. 3 6 9.25 0. 3 5 9 60